Buscar
Mostrando ítems 91-100 de 633
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Corneal densitometry patterns in Descemet membrane endothelial keratoplasty and Descemet stripping automated keratoplasty
(Springer Nature, 2021-03)
Purpose: To compare corneal densitometry in a consecutive series of 52 endothelial keratoplasties (DMEK/DSAEK) using a Scheimpflug-based device after six months of follow-up. Methods: Corneal densitometry (CD) values of ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Magnetocaloric effect in Mn-containing Hitperm-type alloys.
(AIP Publishing, 2007)
The magnetocaloric effect of Fe60−xMnxCo18Nb6B16 x=0,2,4 is studied. Mn addition decreases the Curie temperature of the alloys but also reduces the peak entropy change and the refrigerant capacity of the material. The ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Tailoring of magnetocaloric response in nanostructured materials: Role of anisotropy
(2008-03-25)
The magnetocaloric response of an ensemble of oriented uniaxial magnetic objects, perpendicularly magne- tized to their easy axes, for temperatures close to the blocking temperature is calculated with the aim of demonstrating ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Low-frequency excitations in glassy selenium: A comparison of neutron-scattering and molecular-dynamics results
(American Institute of Physics Publising LLC, 1993)
The microscopic low-frequency dynamics of glassy selenium is investigated by means of the concurrent use of neutron inelastic scattering and computer simulations. A separation of the dynamic response in terms of intra- and ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Influence of Thermal and Magnetic History on Direct DTad Measurements of Ni49+xMn36-xIn15 Heusler Alloys
(MDPI, 2019-10-25)
In the present work, using Heusler Ni49+xMn36-xIn15 (with x = 0 and 0.5) alloys, it is shown that the choice of the appropriate measurement protocol (erasing the prior state of the sample in between experiments) in DTad ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Enhancement of the Magnetic Refrigerant Capacity in Partially Amorphous Fe 70Zr 30 Powders Obtained by Mechanical Alloying
(Elsevier, 2012)
After mechanical alloying Fe 70Zr 30 composition from pure starting powders, an amorphous phase with Curie temperature T C = 244 K and an intermetallic compound (that should be non-stoichiometric Zr-rich fcc Fe 2Zr phase) ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Thermal transport in glassy selenium: The role of low-frequency librations
(American Institute of Physics Publising LLC, 1994)
The experimental curves giving the temperature dependence of the thermal conductivity of glassy selenium are considered in detail. The observed behavior can be taken into account quantitatively if the densities of states ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
The magnetocaloric effect in materials with a second order phase transition: Are T C and T peak necessarily coincident?
(AIP Publishing, 2009)
Using the Arrott–Noakes equation of state it is shown that the Curie point TC and the temperature where the magnetic entropy change is maximum Tpeak coincide only in the mean field approximation, but the Heisenberg ...
Artículo
![Con acceso al texto completo Icon](/themes/idUS//images/acceso/opened_access.png)
Milling effects on magnetic properties of melt spun Fe-Nb-B alloy
(AIP Publishing, 2014-02-25)
Fe75Nb10B15 amorphous ribbons were grinded via ball milling to produce powder samples preserving the amorphous microstructure. A continuous increase of the Curie temperature with the milling time is observed ...