dc.identifier.citationRodríguez Pérez, A., Delgado Restituto, M. y Rodríguez Vázquez, Á.B. (2014). Self-calibration of neural recording sensors. En 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings Lausanne, Suiza: Institute of Electrical and Electronics Engineers.
dc.identifier.isbn978-1-4799-2346-5es
dc.identifier.issn2163-4025es
dc.identifier.urihttps://hdl.handle.net/11441/89479
dc.description.abstractThis paper reports a calibration system for automatically adjusting the bandpass and gain characteristics of programmable E×G sensors. The calibration mechanism of the bandpass characteristic is based on a mixed-signal tuning loop which uses as feedback signal the output of the data converter following the signal conditioning of the E×G sensor. Intended high-pass and low-pass frequency poles of the transfer function are injected into the loop by means of a direct frequency synthesizer followed by a smoothing atenuator.es
dc.description.sponsorshipMinisterio de Ciencia e Innovación TEC2012-33634es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherInstitute of Electrical and Electronics Engineerses
dc.relation.ispartof2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings (2014),
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleSelf-calibration of neural recording sensorses
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Electrónica y Electromagnetismoes
dc.relation.projectIDTEC2012-33634es
dc.relation.publisherversionhttps://doi.org/10.1109/BioCAS.2014.6981813es
dc.identifier.doi10.1109/BioCAS.2014.6981813es
idus.format.extent4 p.es
dc.eventtitle2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedingses
dc.eventinstitutionLausanne, Suizaes
dc.identifier.sisius20805336es

FicherosTamañoFormatoVerDescripción
Self-calibration of Neural.pdf674.0KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional