dc.creatorKarami, Ehsanes
dc.creatorKhalilinia, Ahmades
dc.creatorBali, Afshares
dc.creatorRouzbehi, Kumarses
dc.date.accessioned2021-07-30T11:19:26Z
dc.date.available2021-07-30T11:19:26Z
dc.date.issued2020
dc.identifier.citationKarami, E., Khalilinia, A., Bali, A. y Rouzbehi, K. (2020). Monte-Carlo-based simulation and investigation of 230 kV transmission lines outage due to lightning. High Voltage, 5 (1), 83-91.
dc.identifier.issn2397-7264es
dc.identifier.urihttps://hdl.handle.net/11441/116566
dc.description.abstractHere, using the probabilistic evaluation based on the Monte Carlo method, back-flashover rate and shielding failure flashover rate of 230 kV overhead transmission lines in the western regions of Iran are evaluated. To such an aim, first, the number of thunderstorm days per year is collected from the reported weather information in order to determine the ground flash density. Then, using MRU-200 equipment, the tower-footing resistance of several towers is measured. Matlab® software is used in order to produce lightning surges considering its probabilistic nature and randomly distribution on the ground to evaluate striking distance based on the geometric model. Then, calculated parameters are transferred to EMTP-RV software by establishing a link to perform the transient simulation and report the results for modelled 230 kV transmission line. Finally, considering IEEE-1243 standard, it is shown that due to high ground flash density, using 230 kV tower with one shield wire is not sufficient to protect the line against lightning phenomena.es
dc.formatapplication/pdfes
dc.format.extent9 p.es
dc.language.isoenges
dc.publisherWiley Open Accesses
dc.relation.ispartofHigh Voltage, 5 (1), 83-91.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMonte Carlo methodes
dc.subjecttransmission lineses
dc.subjectlightninges
dc.titleMonte-Carlo-based simulation and investigation of 230 kV transmission lines outage due to lightninges
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería de Sistemas y Automáticaes
dc.relation.publisherversionhttps://ietresearch.onlinelibrary.wiley.com/action/doSearch?AllField=Monte-Carlo-based+simulation+and+investigation+of+230+kV+transmission+lines+outage+due+to+lightning&SeriesKey=23977264es
dc.identifier.doi10.1049/hve.2019.0147es
dc.journaltitleHigh Voltagees
dc.publication.volumen5es
dc.publication.issue1es
dc.publication.initialPage83es
dc.publication.endPage91es

FicherosTamañoFormatoVerDescripción
Monte Carlo based simulation.pdf1.451MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional