dc.identifier.citationVargas Sierra, S., Liñán Cembrano, G., Roca Moreno, E. y Rodríguez Vázquez, Á.B. (2011). High-dynamic range tone-mapping algorithm for focal plane processors. En V Bioelectronics, Biomedical, and Bioinspired Systems V and Nanotechnology (806807-1-806807-7), Praga, República Checa: The International Society for Optics and Photonics.
dc.identifier.isbn9780819486578es
dc.identifier.urihttps://hdl.handle.net/11441/89215
dc.description.abstractThis paper presents a Dynamic Range improvement technique which is specially well-suited to be implemented in Focal Plane Processors (FPP) due to its very limited computing requirements since only local memories, little digital control and a comparator are required at the pixel level. The presented algorithm employs measurements during exposure time to create a 4-bit non-linear image whose histogram determines the shape of the tone-mapping curve which is applied to create the final image. Simulations results over a highly bimodal 120dB image are presented showing that both the highly and poorly illuminated parts of the image keep a sufficient level of details.es
dc.description.sponsorshipMinisterio de Ciencia e Innovación TEC2009-11812es
dc.description.sponsorshipJunta de Andalucía 2006-TIC-2352es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherThe International Society for Optics and Photonicses
dc.relation.ispartofV Bioelectronics, Biomedical, and Bioinspired Systems V and Nanotechnology (2011), p 806807-1-806807-7
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleHigh-dynamic range tone-mapping algorithm for focal plane processorses
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Electrónica y Electromagnetismoes
dc.relation.projectIDTEC2009-11812es
dc.relation.projectID2006-TIC-2352es
dc.relation.publisherversionhttp://dx.doi.org/10.1117/12.889448es
dc.identifier.doi10.1117/12.889448es
idus.format.extent7 p.es
dc.publication.initialPage806807-1es
dc.publication.endPage806807-7es
dc.eventtitleV Bioelectronics, Biomedical, and Bioinspired Systems V and Nanotechnologyes
dc.eventinstitutionPraga, República Checaes

FicherosTamañoFormatoVerDescripción
High-dynamic range tone-mapping.pdf671.2KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional