Mostrar el registro sencillo del ítem

Ponencia

dc.creatorLeñero Bardallo, Juan Antonioes
dc.creatorSerrano Gotarredona, María Teresaes
dc.creatorLinares Barranco, Bernabées
dc.date.accessioned2018-10-09T11:37:12Z
dc.date.available2018-10-09T11:37:12Z
dc.date.issued2009
dc.identifier.citationLeñero Bardallo, J.A., Serrano Gotarredona, M.T. y Linares Barranco, B. (2009). A spatial calibrated AER contrast retina with adjustable contrast threshold. En XXIV Conference on Design of Circuits and Integrated Systems, Zaragoza.
dc.identifier.urihttps://hdl.handle.net/11441/79235
dc.description.abstractAddress Event Representation (AER) is an emergent technology for assembling modular multi-blocks bio-inspired sensory and processing systems. Visual sensors (retinae) are among the first AER modules to be reported since the introduction of the technology. Spatial contrast AER retinae are of special interest since they provide highly compressed data flow without reducing the relevant information required for performing recognition. Reported AER contrast retinae perform a contrast computation based on the ratio between a pixel’s local light intensity and a spatially weighted average of its neighbourhood. This results in compact circuits, but with the penalty of all pixels generating output signals even if they sensed no contrast. In this paper we present a spatial contrast retina with bipolar output: contrast is computed as the relative difference between a pixel’s local light and its weighted spatial average. As a result, contrast includes a sign and the output will be zero if there is no contrast. Furthermore, an adjustable thresholding mechanism has been included, such that pixels remain silent until they sense an absolute contrast above the adjustable threshold. The pixel contrast computation circuit is based on Boahen’s Biharmonic operator contrast circuit, which has been improved to include mismatch calibration and adaptive current based biasing. As a result, the contrast computation circuit shows much less mismatch, is almost insensitive to ambient light illumination, and biasing is much less critical than in the original voltage biasing scheme. A full AER retina version has been fabricated. In the present paper we provide simulation and preliminary experimental results.es
dc.description.sponsorshipUnión Europea (NABAB) 216777es
dc.description.sponsorshipEspaña Beca (SAMANTA2)TEC2006-11730-C03-01es
dc.description.sponsorshipAndalucía Beca (Brain Sistemas) P06TIC01417es
dc.formatapplication/pdfes
dc.language.isoenges
dc.relation.ispartofXXIV Conference on Design of Circuits and Integrated Systems (2009), p 1-6
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleA spatial calibrated AER contrast retina with adjustable contrast thresholdes
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Arquitectura y Tecnología de Computadoreses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Electrónica y Electromagnetismoes
dc.relation.projectIDNABAB 216777es
dc.relation.projectIDTEC2006-11730-C03-01es
dc.relation.projectIDP06TIC01417es
dc.relation.publisherversionhttp://dcis2009.unizar.es/es
idus.format.extent6 p.es
dc.publication.initialPage1es
dc.publication.endPage6es
dc.eventtitleXXIV Conference on Design of Circuits and Integrated Systemses
dc.eventinstitutionZaragozaes
dc.contributor.funderEuropean Union (UE)

FicherosTamañoFormatoVerDescripción
A Spatial Calibrated.pdf342.5KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional