Mostrar el registro sencillo del ítem

Artículo

dc.creatorCalero, Víctores
dc.creatorGarcía Sánchez, Pabloes
dc.creatorHonrado, Carloses
dc.creatorRamos Reyes, Antonioes
dc.creatorMorgan, Hyweles
dc.date.accessioned2023-02-03T18:14:59Z
dc.date.available2023-02-03T18:14:59Z
dc.date.issued2019
dc.identifier.citationCalero, V., García Sánchez, P., Honrado, C., Ramos Reyes, A. y Morgan, H. (2019). AC electrokinetic biased deterministic lateral displacement for tunable particle separation. Lab on a Chip, 19 (8), 1386-1396. https://doi.org/10.1039/c8lc01416g.
dc.identifier.issn1473-0197es
dc.identifier.issn1473-0189es
dc.identifier.urihttps://hdl.handle.net/11441/142435
dc.description.abstractWe describe a novel particle separation technique that combines deterministic lateral displacement (DLD) with orthogonal electrokinetic forces. DLD is a microfluidic technique for continuous flow particle separation based on size. We describe new tunable devices that use a combination of AC electric fields with DLD to separate particles below the critical diameter. Planar electrodes were integrated into a classical DLD device to produce a force orthogonal to the fluid flow direction. Experiments with 3.0 μm, 1.0 μm and 500 nm diameter microspheres show that at low frequencies (up to 500 Hz) particles oscillate in the direction of the field due to electrophoretic (EP)/electroosmotic (EO) forces. As the frequency of the field increases, the amplitude of these oscillations vanishes and, eventually dielectrophoresis (DEP) becomes the dominant electrokinetic force on the particles (DEP arises from electric field inhomogeneities caused by the presence of the DLD posts). Both mechanisms alter the paths of the particles inside the DLD devices leading to enhanced sorting of particles below the critical diameter of the device.es
dc.description.sponsorshipMinisterio de Educación y Cultura (MEC) FIS2014-54539Pes
dc.formatapplication/pdfes
dc.format.extent15 p.es
dc.language.isoenges
dc.publisherRoyal Society of Chemistryes
dc.relation.ispartofLab on a Chip, 19 (8), 1386-1396.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleAC electrokinetic biased deterministic lateral displacement for tunable particle separationes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Electrónica y Electromagnetismoes
dc.relation.projectIDFIS2014-54539Pes
dc.relation.publisherversionhttps://doi.org/10.1039/c8lc01416ges
dc.identifier.doi10.1039/c8lc01416ges
dc.journaltitleLab on a Chipes
dc.publication.volumen19es
dc.publication.issue8es
dc.publication.initialPage1386es
dc.publication.endPage1396es
dc.contributor.funderMinisterio de Educación y Cultura (MEC). Españaes

FicherosTamañoFormatoVerDescripción
AC electrokinetic biased.pdf1.566MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional