Comparative study of the fatigue strength of dental implast systems with preangled and straight connecting parts
Autor/es | Ayllón Guerola, Juan Manuel
Mitjavila Samayoa, Javier Eduardo Navarro Pintado, Carlos Domínguez Abascal, Jaime |
Departamento | Universidad de Sevilla. Departamento de Ingeniería Mecánica y de Fabricación |
Fecha de publicación | 2016 |
Fecha de depósito | 2022-01-31 |
Publicado en |
|
Resumen | Los implantes dentales deben pasar una certificación donde se determina su resistencia a fatiga según la norma internacional ISO 14801. En esta norma se puede distinguir entre implantes angulados ... Los implantes dentales deben pasar una certificación donde se determina su resistencia a fatiga según la norma internacional ISO 14801. En esta norma se puede distinguir entre implantes angulados y rectos. En algunos países se exige obtener esta curva de fatiga para el implante angulado aunque ya se haya obtenido para el mismo implante pero recto. En este trabajo se muestra tanto experimental como analíticamente que el angulado es más resistente que el recto. Además, también se muestra que solamente sería necesario ensayar de un tipo, o angulado o recto, y a partir de ahí obtener la curva correspondiente para el otro. Para ello se han ensayado implantes rectos y angulados para dos modelos de implantes, mostrándose las vidas obtenidas en función de una tensión equivalente. También se analiza el posible efecto sobre la vida a fatiga de la variación de distintos parámetros de la geometría del implante. Dental implants need to pass a certification where their fatigue strength is determined following the international standard ISO 14801. This standard distinguishes between straight and pre-angled ... Dental implants need to pass a certification where their fatigue strength is determined following the international standard ISO 14801. This standard distinguishes between straight and pre-angled connecting parts. In some countries, it is obligatory to obtain the fatigue curve for the pre-angled implant although it may have already been obtained for the straight one. This paper shows experimentally and analytically that the implant with pre-angled connecting part is more resistant that the straight implant. Furthermore, it is shown that only one type of implant, either straight or pre-angled, needs to be tested and from this result the fatigue curve of the other one can be inferred. For this purpose, various sets of implants, straight and pre-angled for two different designs, have been tested, showing the fatigue lives against an equivalent stress. Finally, the effect over fatigue life of different geometric parameters has been analysed. |
Identificador del proyecto | DPI2014-59160-P |
Cita | Ayllón Guerola, J.M., Mitjavila Samayoa, J.E., Navarro Pintado, C. y Domínguez Abascal, J. (2016). Comparative study of the fatigue strength of dental implast systems with preangled and straight connecting parts. Anales de Mecánica de la Fractura, 33, 51-56. |
Ficheros | Tamaño | Formato | Ver | Descripción |
---|---|---|---|---|
Anales33-007.pdf | 903.2Kb | [PDF] | Ver/ | |