Perfil del autor: Yúfera García, Alberto
Datos institucionales
Nombre | Yúfera García, Alberto |
Departamento | Tecnología Electrónica |
Área de conocimiento | Tecnología Electrónica |
Categoría profesional | Catedrático de Universidad |
Correo electrónico | Solicitar |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Estadísticas
-
Nº publicaciones
65
-
Nº visitas
7674
-
Nº descargas
7745
Publicaciones |
---|
Artículo
![]() Electrical pulse stimulation parameters modulate N2a neuronal differentiation
(Springer Nature, 2024)
Electrical pulse stimulation has been used to enhance the differentiation or proliferation of neuronal progenitor cells ... |
Artículo
![]() Electrical pulse stimulation parameters modulate N2a neuronal differentiation
(Springer Nature, 2024)
Electrical pulse stimulation has been used to enhance the differentiation or proliferation of neuronal progenitor cells ... |
Artículo
![]() Body posture determination for Heart Failure patients from ankle orientation measurements
(Institute of Electrical and Electronics Engineers, 2023)
Heart-Failure (HF) is among the leading hospitalization causes in modern healthcare systems. In this paper, a method for ... |
Artículo
![]() Predictive Cell Culture Time Evolution Based on Electric Models
(Multidisciplinary Digital Publishing Institute (MDPI), 2023)
Obtaining cell concentration measurements from a culture assay by using bioimpedance is a very useful method that can be ... |
Artículo
![]() From Bioimpedance to Volume Estimation: A Model for Edema Calculus in Human Legs
(MDPI, 2023)
Heart failure (HF) is a severe disease and one of the most important causes of death in our society nowadays. A significant ... |
Artículo
![]() Oscillation-Based Spectroscopy for Cell-Culture Monitorization
(Frontiers Media, 2022)
Biological Impedance is a physical property related to the state and inherent evolution of biological samples. Among the ... |
Artículo
![]() Bioimpedance Sensing of Implanted Stent Occlusions: Smart Stent
(MDPI, 2022)
Coronary artery disease is one of the most common diseases in developed countries and affects a large part of the population ... |
Artículo
![]() DC electrical stimulation enhances proliferation and differentiation on N2a and MC3T3 cell lines
(Springer Nature, 2022)
Background: Electrical stimulation is a novel tool to promote the differentiation and proliferation of precursor cells. ... |
Tesis Doctoral
![]() Modeling and simulation of non-linear bioelectronic systems applied to cell culture assays
(2021)
Monitoring the properties of biological samples (BS) is expensive in terms of time consumption and cost in resources and ... |
Ponencia
![]() Effects of electrical fields on neuroblastoma (N2A) cell differentiation: preliminary results
(Scitepress, 2021)
This work describes Electrical Stimulations (ES) assays on stem cells. The neuroblastoma (N2A) cell linage was submitted ... |
Artículo
![]() A computer-aided design tool for biomedical OBT sensor tuning in cell-culture assays
(Elsevier, 2021)
Background and objectives: The biomedical engineering must frequently develop sensor designs by in- cluding information ... |
Artículo
![]() Design and Application of Biomedical Circuits and Systems
(MDPI, 2020)
The development of new sensing technologies, biomaterials, microelectronic devices, microfluidic systems and ... |
Artículo
![]() Electrical Modeling of the Growth and Differentiation of Skeletal Myoblasts Cell Cultures for Tissue Engineering
(MDPI, 2020)
In tissue engineering, of utmost importance is the control of tissue formation, in order to form tissue constructs of ... |
Artículo
![]() Alternative General Fitting Methods for Real-Time Cell-Count Experimental Data Processing
(IEEE Computer Society, 2020)
This paper reports two general methods for extraction of cell-electrode electrical model parameters in cell culture (CC) ... |
Tesis Doctoral |
Artículo
![]() Electrical pulse stimulation of skeletal myoblasts cell cultures with simulated action potentials
(Wiley, 2019)
Electrical pulse stimulation has an important effect on skeletal muscle development and maturation. However, the methodology ... |
Ponencia
![]() Circuito de acondicionado CMOS para la monitorización de cultivos celulares
(Universidad de Zaragoza, 2019)
Este trabajo presenta la etapa de lectura de un front-end analógico para la monitorización del crecimiento de un cultivo ... |
Ponencia
![]() Characterization of Implanted Stents through Neointimal Tissue Bioimpedance Simulations
(IEEE Computer Society, 2019)
This work describes how is possible the definition of the light hole or lumen in implanted stents affected by restenosis ... |
Ponencia
![]() A plethysmographic sensor for monitoring volume changes in cardiovascular pathologies
(IEEE Computer Society, 2019)
This paper presents a capacitive system capable of performing leg volume change monitorization in patients suffering from ... |
Artículo
![]() Data-Analytics Modeling of Electrical Impedance Measurements for Cell Culture Monitoring
(MDPI, 2019)
High-throughput data analysis challenges in laboratory automation and lab-on-a-chip devices’ applications are continuously ... |
Artículo
![]() Evaluation of Implanted Stent Occlusion Status Based on Neointimal Tissue Bioimpedance Simulations
(Hindawi, 2019)
This paper describes the characterization of the light hole, also known as the lumen, in implanted stents affected by ... |
Ponencia
![]() Practical Characterization of Cell-Electrode Electrical Models in Bio-Impedance Assays
(ScitePress Digital Library, 2018)
This paper presents the fitting process followed to adjust the parameters of the electrical model associated to a ... |
Artículo
![]() An Empirical-Mathematical Approach for Calibration and Fitting Cell-Electrode Electrical Models in Bioimpedance Tests
(MDPI, 2018)
This paper proposes a new yet efficient method allowing a significant improvement in the on-line analysis of biological cell ... |
Artículo
![]() Remote Cell Growth Sensing Using Self-Sustained Bio-Oscillations
(MDPI, 2018)
A smart sensor system for cell culture real-time supervision is proposed, allowing for a significant reduction in human ... |
Artículo
![]() Sensing Cell-Culture Assays with Low-Cost Circuitry
(Nature Publishing Group, 2018)
An alternative approach for cell-culture end-point protocols is proposed herein. This new technique is suitable for real-time ... |
Ponencia
![]() Monitoring Muscle Stem Cell Cultures with Impedance Spectroscopy
(ScitePress Digital Library, 2018)
The aim of this work is to present a new circuit for the real-time monitoring the processes of cellular growth and ... |
Ponencia
![]() ECG study in practical labs for biomedical engineering training
(Universidad de La Laguna, 2018)
Non-invasive biomedical measurements are one of the most important technological contributions whitin the biomedical ... |
Ponencia
![]() A Tracking Algorithm For Cell Motility Assays in CMOS Systems
(IEEE Computer Society, 2017)
This work proposes a method for the study and real-time monitoring of a single cell on a 2D electrode matrix, of great ... |
Ponencia
![]() Bioimpedance real-time charazterization of neointimal tissue inside stents
(2017)
It is hereby presented a new approach to monitor restenosis in arteries fitted with a stent during an angioplasty. The ... |
Ponencia
![]() A CMOS Tracking System Approach for Cell Motility Assays
(SciTePress Digital Library, 2017)
This work proposes a method for studying and monitoring in real-time a single cell on a 2D electrode matrix, of great ... |
Trabajo Fin de Máster |
Artículo
![]() Real-Time Electrical Bioimpedance Characterization of Neointimal Tissue for Stent Applications
(MDPI, 2017)
To follow up the restenosis in arteries stented during an angioplasty is an important current clinical problem. A new ... |
Ponencia
![]() Monitoring Tissue Evolution on Electrodes with Bio-Impedance Test
(IEEE Computer Society, 2016)
A technique for real-time monitoring of bioimpedances using a Voltage Oscillation (VO) methodology is proposed. The main ... |
Artículo
![]() Towards Bio-impedance Based Labs: A Review
(David Publishing, 2016)
In this article, some of the main contributions to BI (Bio-Impedance) parameter-based systems for medical, biological ... |
Ponencia
![]() Cell-Culture Measurements Using Voltage Oscillations
(IEEE Computer Society, 2016)
A comprehensive system for real-time monitoring of a set of cell-cultures using a Voltage Oscillation (VO) methodology is ... |
Artículo
![]() Microcontroller-Based Sinusoidal Voltage Generation for Electrical Bio-Impedance Spectroscopy Applications
(Scientific Research Publishing, 2016)
A sinusoidal voltage wave generator is proposed based on the use of micro- processor digital signals with programmable ... |
Artículo
![]() The bio-oscillator: A circuit for cell-culture assays
(Institute of Electrical and Electronics Engineers, 2015)
A system for cell-culture real-time monitoring using an oscillation-based approach is proposed. The system transforms a ... |
Artículo
![]() Monolithic integration of Giant Magnetoresistance (GMR) devices onto standard processed CMOS dies
(Elsevier, 2014)
Giant Magnetoresistance (GMR) based technology is nowadays the preferred option for low magnetic fields sensing in disciplines ... |
Ponencia
![]() Cell-culture Real-Time Monitoring: an Oscillation-based Approach
(Universidad de Sevilla, 2013)
In this work, a way to cell-culture real-time monitoring system by means of the Oscillation-Based Test (OBT) methodology ... |
Artículo
![]() Cell-culture real time monitoring based on bio-impedance measurements
(International Frequency Sensor Association, 2012)
This paper proposes the application of a cell-microelectrode model in cell biometry experiments, using the cell-electrode ... |
Artículo
![]() A microscopy technique based on bio-impedance sensors
(Elsevier, 2012)
It is proposed a microscopy for cell culture applications based on impedance sensors. The imagined signals are measured ... |
Artículo
![]() Generation of HDL models for bio-impedance sensor simulation based on microelectrodes
(International Frequency Sensor Association, 2011)
This paper presents a computer tool for automatic analysis of cell culture images. The program allows the extraction of ... |
Ponencia
![]() Using microelectrode models for real time cell-culture monitoring
(IEEE Computer Society, 2011)
This paper proposes a cell-microelectrode model for cell biometry applications, based on the area overlap as main parameter. ... |
Ponencia
![]() A Microelectrode-Cell Sensor Model for Real Time Monitoring
(IARIA (Association), 2011)
In this paper the application of a cellmicroelectrode model to cell biometry experiments is proposed, using the cell-electrode ... |
Tesis Doctoral |
Ponencia
![]() Automatic Generation of Analog Hardware Description Language (AHDL) Code from Cell Culture Images
(IEEE Computer Society, 2010)
This paper presents a computer tool for automatic analysis of cell culture images. The program allows the extraction of ... |
Ponencia
![]() Herramienta para el aprendizaje de un sistema de adquisición de datos
(2010)
Se presenta un paquete de software didáctico que facilita el proceso de enseñanza/aprendizaje de la electrónica, orientado ... |
Artículo
![]() Design of a CMOS closed-loop system with applications to bio-impedance measurements
(Elsevier, 2010)
This paper proposes a method for impedance measurements based on a closed-loop implementation of CMOS circuits. The proposed ... |
Ponencia
![]() El Entorno: Vision - E Laboratory
(2010)
Se presenta un entorno de programación para el estudio y desarrollo de algoritmos de tratamiento de imágenes y visión por ... |
Ponencia
![]() El entorno: Vision-e Laboratory
(Universidad Politécnica de Madrid, 2010)
Se presenta un entorno de programación para el estudio y desarrollo de algoritmos de tratamiento de imágenes y visión por ... |
Ponencia
![]() A CMOS Bio-Impedance Measurement System
(IEEE Computer Society, 2009)
This paper proposes a new method for bio-impedance measurement useful to 2D processing of cell cultures. It allows ... |
Artículo
![]() A highly sensitive microsystem based on nanomechanical biosensors for genomics applications
(Elsevier, 2006)
Microcantilever-based biosensors are a promising tool to detect biomolecular interactions in a direct way with high accuracy. ... |
Ponencia
![]() Software para el aprendizaje de convertidores digitales-analógicos.
(Universidad Politécnica de Madrid, 2006)
Se presenta un paquete de software didáctico que facilita el proceso de enseñanza/ aprendizaje de la electrónica, en ... |
Artículo
![]() A Tissue Impedance Measurement Chip for Myocardial Ischemia Detection
(IEEE Computer Society, 2005)
In this paper, the design of a specific integrated circuit for the measurement of tissue impedances is presented. The circuit ... |
Ponencia
![]() A first order incremental analog to digital converter based on continuous time circuits
(International Measurements Conference, 2003)
In this paper, an incremental Analog-to- Digital Converter (ADC) designed as part of the signalconditioning circuitry for ... |
Artículo
![]() Aprendizaje interdisciplinar de la electrónica y las comunicaciones
(Universidad de Sevilla: Instituto de Ciencias de la Educación, 2003)
En este proyecto de innovación docente se pretende profundizar en el conocimiento de la base teórica, la construcción de ... |
Ponencia
![]() A charge correction cell for FGMOS-based circuits
(IEEE Computer Society, 2003)
This paper describes a novel cell used in circuits with Floating Gate MOS transistors (FGMOS) to compensate variations in ... |
Ponencia
![]() A micropower log domain FGMOS filter
(IEEE Computer Society, 2002)
In this paper, a CMOS implementation of a low voltage micropower logarithmic biquad based on floating gate MOS transistors ... |
Artículo
![]() A Low-Voltage Floating-Gate MOS Biquad
(Hindawi Publishing Corporation, 2001)
A second-order gm-C filter based on the Floating-Gate MOS (FGMOS) technique is presented. It uses a new fully differential ... |
Ponencia
![]() A 1.25V FGMOS Filter Using Translinear Circuits
(IEEE Computer Society, 2001)
This paper presents a new low voltage/low power filter design based on Floating-Gate MOS (FGMOS) transistors. FGMOS ... |
Ponencia
![]() A low-voltage /spl radic/x floating-gate MOS integrator
(IEEE Computer Society, 2000)
In this paper, the design and simulation results of an IV integrator using floating gate MOS (FGMOS) transistor techniques ... |
Ponencia
![]() Programmable low-voltage continuous-time filter for audio applications
(IEEE Computer Society, 1999)
The implementation of a continuous-time filter (CTF) useful for audio frequency applications is presented in this paper. ... |
Ponencia
![]() Modelado de tiristores mediante simulación eléctrica
(Universidad de Sevilla, 1996)
|
Tesis Doctoral
![]() Aplicación de la técnica de corrientes conmutadas al diseño de filtros de onda analógicos
(1994)
En este trabajo de Tesis se demuestra la realización de FDO mediante técnicas de corrientes conmutadas, SI, en el marco ... |
Ponencia
![]() A study of the sensitivity of switched-current wave analog filters to mismatching and clock-feedthrough errors
(IEEE Computer Society, 1994)
The influence of the main source of errors in Switched-Current (SI) filters over the performance of Wave Analog Filters ... |