• Ponencia
      Icon

      A 32 Input Multiplexed Channel Analog Front-End with Spatial Delta Encoding Technique and Differential Artifacts Compression 

      Pérez Prieto, Norberto; Fiorelli, Rafaella; Valtierra, José Luis; Pérez García, Pablo; Delgado Restituto, Manuel ; Rodríguez Vázquez, Ángel Benito (IEEE Computer Society, 2019)
      This paper describes a low-noise, low-power and high dynamic range analog front-end intended for sensing neural signals. ...
    • Ponencia
      Icon

      A CMOS Tracking System Approach for Cell Motility Assays 

      Martínez Gómez, Cristina; Olmo Fernández, Alberto; Huertas Sánchez, Gloria; Pérez García, Pablo; Maldonado-Jacobi, Andrés; Yúfera García, Alberto (SciTePress Digital Library, 2017)
      This work proposes a method for studying and monitoring in real-time a single cell on a 2D electrode matrix, of great ...
    • Ponencia
      Icon

      A plethysmographic sensor for monitoring volume changes in cardiovascular pathologies 

      Rando, Enrique; Pérez García, Pablo; Huertas Sánchez, Gloria; Yúfera García, Alberto (IEEE Computer Society, 2019)
      This paper presents a capacitive system capable of performing leg volume change monitorization in patients suffering ...
    • Ponencia
      Icon

      A Tracking Algorithm For Cell Motility Assays in CMOS Systems 

      Martínez Gómez, Cristina; Olmo Fernández, Alberto; Huertas Sánchez, Gloria; Pérez García, Pablo; Maldonado-Jacobi, Andrés; Yúfera García, Alberto (IEEE Computer Society, 2017)
      This work proposes a method for the study and real-time monitoring of a single cell on a 2D electrode matrix, of great ...
    • Ponencia
      Icon

      Cell-Culture Measurements Using Voltage Oscillations 

      Maldonado-Jacobi, Andrés; Huertas Sánchez, Gloria; Rueda Rueda, Adoración; Huertas, José Luis; Pérez García, Pablo; Yúfera García, Alberto (IEEE Computer Society, 2016)
      A comprehensive system for real-time monitoring of a set of cell-cultures using a Voltage Oscillation (VO) methodology ...
    • Ponencia
      Icon

      Characterization of Implanted Stents through Neointimal Tissue Bioimpedance Simulations 

      Portillo Anaya, J.M.; Pérez García, Pablo; Huertas Sánchez, Gloria; Olmo Fernández, Alberto; Serrano, J. A.; Maldonado Jacobi, Andrés; Yúfera García, Alberto (IEEE Computer Society, 2019)
      This work describes how is possible the definition of the light hole or lumen in implanted stents affected by restenosis ...
    • Ponencia
      Icon

      ECG study in practical labs for biomedical engineering training 

      Pérez García, Pablo; Olmo Fernández, Alberto; Yúfera García, Alberto (Universidad de La Laguna, 2018)
      Non-invasive biomedical measurements are one of the most important technological contributions whitin the biomedical ...
    • Ponencia
      Icon

      Monitoring Muscle Stem Cell Cultures with Impedance Spectroscopy 

      Yuste, Yaiza; Serrano, Juan A.; Olmo Fernández, Alberto; Maldonado-Jacobi, Andrés; Pérez García, Pablo; Huertas Sánchez, Gloria; Pereira Arenas, Sheila; Portilla de Juan, Fernando de la; Yúfera García, Alberto (ScitePress Digital Library, 2018)
      The aim of this work is to present a new circuit for the real-time monitoring the processes of cellular growth and ...
    • Ponencia
      Icon

      Monitoring Tissue Evolution on Electrodes with Bio-Impedance Test 

      Maldonado Jacobi, Andrés; Pérez García, Pablo; Huertas Sánchez, Gloria; Yúfera García, Alberto; Rueda, A.; Huertas, J. L. (IEEE Computer Society, 2016)
      A technique for real-time monitoring of bioimpedances using a Voltage Oscillation (VO) methodology is proposed. The main ...
    • Ponencia
      Icon

      Practical Characterization of Cell-Electrode Electrical Models in Bio-Impedance Assays 

      Serrano, Juan A.; Pérez García, Pablo; Maldonado-Jacobi, Andrés; Martín Rubio, María Esther; Olmo Fernández, Alberto; Daza Navarro, María Paula; Huertas Sánchez, Gloria; Yúfera García, Alberto (ScitePress Digital Library, 2018)
      This paper presents the fitting process followed to adjust the parameters of the electrical model associated to a ...