dc.description.abstractEl objeto del presente estudio es el análisis energético del edificio de consultas externas “Policlínico” del Hospital Universitario Virgen Macarena de Sevilla. Este análisis se basa en las demandas y consumos del edificio, así como en su nivel de emisiones de CO2. Se realiza un diagnóstico del edificio para identificar sus patologías y se estudian distintas medidas de ahorro energético destinadas a reducir sus efectos. Cada una de estas medidas es analizada individualmente en función del resultado que produciría su implantación en la calificación energética del edificio. Además se realiza un estudio económico de cada una de ellas para determinar su viabilidad. Las medidas de ahorro energético se aplican tanto a la envolvente del edificio como a sus instalaciones. Todas las medidas que resultan viables se agrupan en una propuesta conjunta y se realiza un análisis energético del edificio tras la implantación de todas ellas. Como resultado se obtiene una reducción del 70 % tanto en emisiones de CO2 como en consumo de energía primaria no renovable, además, el consumo total de energía eléctrica procedente de la red se reduce en un 71%, esto es igual a un ahorro anual de 40.142,18 €. Todo ello con una inversión reducida y causando el mínimo perjuicio al desarrollo de la actividad en el edificio.es
dc.description.abstractThe purpose of this document is the analysis of the building for external medical consultation “Policlínico” of the Virgen Macarena Hospital in Seville. This analysis is based on the demands and consumptions of the building, as well as on its level of CO2 emissions. A diagnosis of the building is made to identify its pathologies and different energy saving measures are studied to reduce their effects. Each of these measures is analyzed individually based in the energy rating of the building obtained after its implementation. In addition, an economic study of each of them is carried out to determine its viability. The energy saving measures will be applied to the envelope of the building and its facilities. All the measures that are viable are grouped in a joint proposal and an energy analysis of the building is carried out after the implementation of all of them. As a result, a 70% reduction in both CO2 emissions and non-renewable primary energy consumption is obtained, in addition, the total consumption of electric power from the network is reduced by 71 %, this is equal to an annual saving of 42.142,18 €. This can be made with a reduced investment and causing minimal damage to the development of the activity in the building.es
dc.formatapplication/pdfes
dc.language.isospaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleEstudio de mejora de la eficiencia energética del edificio de consultas externas "policlínico" del H.U.V.M (Sevilla)es
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas II (ETSIE)es
dc.description.degreeUniversidad de Sevilla. Grado en Edificaciónes
idus.format.extent275es

FicherosTamañoFormatoVerDescripción
aopfgetsie193.pdf44.06MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional