Mostrar el registro sencillo del ítem

Artículo

dc.creatorRamos Payán, María Doloreses
dc.creatorSantigosa Murillo, Eliaes
dc.creatorCoello, Jordies
dc.creatorBello López, Miguel Ángeles
dc.date.accessioned2024-08-19T10:56:19Z
dc.date.available2024-08-19T10:56:19Z
dc.date.issued2018-06
dc.identifier.citationRamos Payán, M.D., Santigosa Murillo, E., Coello, J. y Bello López, M.Á. (2018). A comprehensive study of a new versatile microchip device based liquid phase microextraction for stopped-flow and double-flow conditions. Journal of Chromatography A, 1556, 29-36. https://doi.org/10.1016/j.chroma.2018.04.051.
dc.identifier.issn0021-9673es
dc.identifier.issn1873-3778es
dc.identifier.urihttps://hdl.handle.net/11441/161989
dc.description.abstractA new geometry for a versatile microfluidic-chip device based liquid phase microextraction was developed in order to enhance the preconcentration in microfluidic chips and also to enable double-flow and stopped-flow working modes. The microchip device was combined with a HPLC procedure for the simultaneous determination of two different families as model analytes, which were parabens and non-steroidal anti-inflammatories (NSAIDs): Ethyl 4-hydroxybenzoate (Et-P), Propyl 4-hydroxybenzoate (Pr-P), Butyl 4-hydroxybenzoate (Bu-P), IsoButyl 4-hydroxybenzoate (iBu-P), salycilic acid (SAC), ketoprofen (KET), naproxen (NAX), diclofenac (DIC) and ibuprofen (IBU) in urine samples. The new miniaturized microchip proposed in this work allows not only the possibility of working in double-flow conditions, but also under stagnant conditions (stopped-flow) (SF-μLPME). The sample (pH 1.5) was delivered to the SF-μLPME at 20 μL min−1 while keeping the acceptor phase (pH 11.75) under stagnant conditions during 20 min. The highest enrichment factors (between 16 and 47) were obtained under stopped-flow conditions at 20 μL min−1 (sample flow rate) after 20 min extraction; whereas the extraction efficiencies were within the range of 27–81% for all compounds. The procedure provided very low detection limits between 0.7 and 8.5 μg L−1 with a sample volume consumption of 400 μL. Parabens and NSAIDs have successfully been extracted from urine samples with excellent clean up and recoveries over 90% for all compounds. In parallel, the new device was also tested under double flow conditions, obtaining good but lower enrichment factors (between 9 and 20) and higher extraction efficiencies (between 45 and 95) after 7 min extraction, consuming a volume sample of 140 μL. The versatile device offered very high extraction efficiencies and good enrichment factor for double flow and stopped-flow conditions, respectively. In addition, this new miniaturized SF-μLPME device significantly reduced costs compared to the existing analytical techniques for sample preparation since this microchip require few microliters of sample and reagents and it is reusable.es
dc.description.sponsorshipMinisterio de Educación y Ciencia TEC2006-79367-C2-1-Res
dc.formatapplication/pdfes
dc.format.extent8 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofJournal of Chromatography A, 1556, 29-36.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleA comprehensive study of a new versatile microchip device based liquid phase microextraction for stopped-flow and double-flow conditionses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Química Analíticaes
dc.relation.projectIDTEC2006-79367-C2-1-Res
dc.relation.publisherversionhttps://dx.doi.org/10.1016/j.chroma.2018.04.051es
dc.identifier.doi10.1016/j.chroma.2018.04.051es
dc.journaltitleJournal of Chromatography Aes
dc.publication.volumen1556es
dc.publication.initialPage29es
dc.publication.endPage36es
dc.contributor.funderMinisterio de Educación y Ciencia (MEC). Españaes

FicherosTamañoFormatoVerDescripción
10.1016j.chroma.2018.04.051.pdf679.7KbIcon   [PDF] Ver/Abrir   Versión aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional