Mostrar el registro sencillo del ítem

Artículo

dc.creatorFernández Olavarria, Anaes
dc.creatorGutiérrez Corrales, Aídaes
dc.creatorGonzález Martín, María Isabeles
dc.creatorTorres-Lagares, Danieles
dc.creatorTorres Carranza, Eusebioes
dc.creatorSerrera Figallo, María de los Ángeleses
dc.date.accessioned2024-07-12T13:04:07Z
dc.date.available2024-07-12T13:04:07Z
dc.date.issued2023
dc.identifier.citationFernández Olavarria, A., Gutiérrez Corrales, A., González Martín, M.I., Torres-Lagares, D., Torres Carranza, E. y Serrera Figallo, M.d.l.Á. (2023). Influence of different drilling protocols and bone density on the insertion torque of dental implants. Medicina oral, patología oral y cirugía bucal, 28 (4), e385-e394. https://doi.org/10.4317/medoral.25804.
dc.identifier.issn1698-4447es
dc.identifier.issn1698-6946es
dc.identifier.urihttps://hdl.handle.net/11441/161341
dc.description.abstractBackground: The insertion torque of dental implants will depend on a combination of different factors such as bone density, the design of the implant and the drilling protocol used. However, it is not clear how the interaction of these factors affects the final insertion torque and which drilling protocol should be used in each clinical situa tion. The aim of this work is to analyse the influence of bone density, implant diameter and implant length on the insertion torque using different drilling protocols. Material and Methods: An experimental study was carried out in which the maximum insertion torque was meas ured, in standardised polyurethane blocks (Sawbones Europe AB) of four densities, for M12 Oxtein dental im plants (Oxtein, Spain) with diameters of 3.5, 4.0, 4.5 and 5mm, and lengths of 8.5mm, 11.5mm and 14.5mm. All these measurements were carried out following four drilling protocols, a standard protocol, adding a bone tap, cortical drill or conical drill. In this way, a total of 576 samples were obtained. For the statistical analysis, the table of confidence intervals, mean, standard deviation and covariance was carried out, in total and grouped by the parameters used. Results: The insertion torque for D1 bone obtained very high levels, reaching 77± 6.95 N/cm, these values im proved with the use of conical drills. In D2 bone, the mean torque obtained was 37.89± 13.70N/cm, with values within the standard. In D3 and D4 bone significantly low torques were obtained with values of 14.97± 4.40N/cm and 9.88± 4.16N/cm (p>0.001) respectively. Conclusions: In D1 bone, conical drills must be incorporated in drilling to avoid excessive torque, while in D3 and D4 bone, these would be contraindicated, as they drastically decrease the insertion torque, which may com promise the treatment.es
dc.formatapplication/pdfes
dc.format.extent10 p.es
dc.language.isoenges
dc.publisherMedicina Oral S.Les
dc.relation.ispartofMedicina oral, patología oral y cirugía bucal, 28 (4), e385-e394.
dc.subjectDental implantes
dc.subjectTorquees
dc.subjectDrilling protocolses
dc.subjectBone densityes
dc.titleInfluence of different drilling protocols and bone density on the insertion torque of dental implantses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.contributor.affiliationInstituto de Biomedicina de Sevilla (IBIS)es
dc.relation.publisherversionhttp://www.medicinaoral.com/medoralfree01/aop/25804.pdfes
dc.identifier.doi10.4317/medoral.25804es
dc.journaltitleMedicina oral, patología oral y cirugía bucales
dc.publication.volumen28es
dc.publication.issue4es
dc.publication.initialPagee385es
dc.publication.endPagee394es

FicherosTamañoFormatoVerDescripción
Influence of different drilling.pdf828.9KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.