Mostrar el registro sencillo del ítem

Artículo

dc.creatorBorroni, Davidees
dc.creatorRocha de Lossada, Carloses
dc.creatorBonci, Paolaes
dc.creatorRechichi, Migueles
dc.creatorRodríguez Calvo de Mora, Marinaes
dc.creatorRachwani-Anil, Rahules
dc.creatorSánchez González, José Maríaes
dc.creatorUrbinati, Facundoes
dc.creatorGarcía Lorente, Maríaes
dc.creatorCarones, Francescoes
dc.date.accessioned2024-06-10T09:15:41Z
dc.date.available2024-06-10T09:15:41Z
dc.date.issued2022
dc.identifier.citationBorroni, D., Rocha de Lossada, C., Bonci, P., Rechichi, M., Rodríguez Calvo de Mora, M., Rachwani-Anil, R.,...,Carones, F. (2022). Glasses-Assisted 3D Display System–Guided Descemet Membrane Endothelial Keratoplasty Tissue Preparation. Cornea, 41 (11), 1444-1446. https://doi.org/10.1097/ICO.0000000000003005.
dc.identifier.issn1536-4798 (electrónico)es
dc.identifier.issn0277-3740 (impreso)es
dc.identifier.urihttps://hdl.handle.net/11441/160137
dc.description.abstractPurpose: The aim of this study was to evaluate the feasibility of Descemet membrane endothelial keratoplasty (DMEK) tissue prep- aration using a glasses-assisted 3-dimensional (3D) display system and to compare it with a conventional surgical microscope. Methods: Healthy pairs of human corneas suitable for penetrating keratoplasty surgery were selected for this study. The tissues were randomly divided into 2 groups. Each pair of corneas had 1 cornea (group 1) prepared with NGENUITY (Alcon) with a 5-second staining time with vision blue, and the fellow cornea (group 2) was prepared using a OPMI Lumera 700 surgical microscope (Carl Zeiss Meditec, Jena, Germany) with a 30-second staining time. DMEK graft preparation time, speed of stripping, graft width, and endothe- lial cell loss were evaluated. Results: Twenty-eight pairs of corneas were included in this study. The graft preparation time was significantly higher in the 3D group than in the conventional group (498 6 147 vs. 418 6 85 seconds, P value = 0.031). The mean speed of stripping was 0.59 6 0.081 mm/s in group 1 and 0.089 6 0.005 mm/s in group 2 (P value = 0.024). The mean endothelial cell density in group 1 and group 2 before tissue preparation was 2162 6 115.21 and 2153 6 122.45, respectively (P value . 0.1). After tissue preparation, the endothelial cell density reduced to 1911 6 150.72 in group 1 and 1998 6 90.72 in group 2 (P value = P value . 0.05). The graft width was 5.05 6 0.71 mm in group 1 and 4.92 6 0.23 mm in group 2 (P value . 0.05). Conclusions: DMEK tissue preparation with 3D display system NGENUITY is feasible with a slightly increased preparation time. The improved visualization allows a reduced staining time that couldes
dc.formatapplication/pdfes
dc.format.extent3 p.es
dc.language.isoenges
dc.publisherLIPPINCOTT WILLIAMS & WILKINSes
dc.relation.ispartofCornea, 41 (11), 1444-1446.
dc.subjectDMEKes
dc.subject3D display systemes
dc.subjectStrippinges
dc.titleGlasses-Assisted 3D Display System–Guided Descemet Membrane Endothelial Keratoplasty Tissue Preparationes
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física de la Materia Condensadaes
dc.relation.publisherversionhttps://dx.doi.org/10.1097/ICO.0000000000003005es
dc.identifier.doi10.1097/ICO.0000000000003005es
dc.journaltitleCorneaes
dc.publication.volumen41es
dc.publication.issue11es
dc.publication.initialPage1444es
dc.publication.endPage1446es

FicherosTamañoFormatoVerDescripción
Glasses-Assisted 3D_Sánchez ...357.5KbIcon   [PDF] Ver/Abrir   Versión aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.