Article
A comparison between active and passive techniques for measurements of radon emanation factors
Author/s | López Coto, I.
Más Balbuena, José Luis San Miguel, E. G. Bolivar, J. P. Sengupta, D. |
Department | Universidad de Sevilla. Departamento de Física Aplicada I |
Publication Date | 2009 |
Deposit Date | 2024-04-16 |
Published in |
|
Abstract | Some radon related parameters have been determined through two different techniques (passive and active) in soil and phosphogypsum samples. Emanation factors determined through these techniques show a good agreement for ... Some radon related parameters have been determined through two different techniques (passive and active) in soil and phosphogypsum samples. Emanation factors determined through these techniques show a good agreement for soil samples while for phosphogympsum samples appear large discrepancies. In this paper, these discrepancies are analyzed and explained if non-controlled radon leakages in the passive technique are taken into account. |
Citation | López Coto, I., Más Balbuena, J.L., San Miguel, E.G., Bolivar, J.P. y Sengupta, D. (2009). A comparison between active and passive techniques for measurements of radon emanation factors. APPLIED RADIATION AND ISOTOPES, 67 (5), 849-853. https://doi.org/10.1016/j.apradiso.2009.01.045. |
Files | Size | Format | View | Description |
---|---|---|---|---|
A comparison between active and ... | 203.8Kb | [PDF] | View/ | |