dc.creator | Pérez Moreno, J. P. | es |
dc.creator | Bolívar, Juan Pedro | es |
dc.creator | García-Tenorio García-Balmaseda, Rafael | es |
dc.creator | Gutiérrez San Miguel, Enrique | es |
dc.creator | Aguado Casas, Juan Luis | es |
dc.creator | Más Balbuena, José Luis | es |
dc.creator | Vaca Galán, Federico | es |
dc.date.accessioned | 2023-05-19T18:28:49Z | |
dc.date.available | 2023-05-19T18:28:49Z | |
dc.date.issued | 2001 | |
dc.identifier.citation | Pérez Moreno, J.P., Bolívar, J.P., García-Tenorio García-Balmaseda, R., Gutiérrez San Miguel, E., Aguado Casas, J.L., Más Balbuena, J.L. y Vaca Galán, F. (2001). A simple method for efficiency calibration of HPGe detectors in gamma-spectrometric measurements. Radiation Physics and Chemistry, 61 (3-6), 437-438. https://doi.org/10.1016/S0969-806X(01)00290-0. | |
dc.identifier.issn | 879-0895 | es |
dc.identifier.issn | 0969-806X | es |
dc.identifier.uri | https://hdl.handle.net/11441/146476 | |
dc.description.abstract | In this paper a simple, rapid and general method for g-ray efficiency calibration of Ge detectors for environmental
samples is presented. This method is based on the use of an active natural solid sample with several g-emissions (in our
case, 226Ra) as the calibrating matrix for determining the full energy peak efficiency (FEPE) ec vs g-emission energy Eg
and the sample height h in a counting cylindrical geometry. The 226Ra activity concentration is determined by a-particle
spectrometry, a method that has previously been validated | es |
dc.format | application/pdf | es |
dc.format.extent | 2 p. | es |
dc.language.iso | eng | es |
dc.publisher | Elsevier | es |
dc.relation.ispartof | Radiation Physics and Chemistry, 61 (3-6), 437-438. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Gamma-spectrometry | es |
dc.subject | Efficiency-calibration | es |
dc.subject | Self-absorption | es |
dc.subject | Sample-height | es |
dc.title | A simple method for efficiency calibration of HPGe detectors in gamma-spectrometric measurements | es |
dc.type | info:eu-repo/semantics/article | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física Aplicada II | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física Aplicada I | |
dc.relation.publisherversion | https://doi.org/10.1016/S0969-806X(01)00290-0 | es |
dc.identifier.doi | 10.1016/S0969-806X(01)00290-0 | es |
dc.journaltitle | Radiation Physics and Chemistry | es |
dc.publication.volumen | 61 | es |
dc.publication.issue | 3-6 | es |
dc.publication.initialPage | 437 | es |
dc.publication.endPage | 438 | es |