Por motivos de mantenimiento se ha deshabilitado el inicio de sesión temporalmente. Rogamos disculpen las molestias.
Artículo
The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour
Autor/es | Callejas, Juan Antonio
Brizuela, Aritza Ríos Carrasco, Blanca Gil, Javier |
Departamento | Universidad de Sevilla. Departamento de Estomatología |
Fecha de publicación | 2022 |
Fecha de depósito | 2023-05-04 |
Publicado en |
|
Resumen | Many studies are being carried out on the particles released during the implantoplasty
process in the machining of dental implants to remove bacterial biofilms. However, there are no
studies on the release of particles ... Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressive frictional loads between the rough titanium implant and the bone tissue. This paper aims to characterize the released particles and determine the release of titanium ions into the physiological environment and their cytocompatibility. For this purpose, 90 dental implants with a neck diameter of 4 mm and a torque of 22 Ncm were placed in 7 fresh cow ribs. The placement was carried out according to the established protocols. The implants had a roughness Ra of 1.92 µm. The arrangement of the particles in the bone tissue was studied by micro-CT, and no particle clusters were observed. The different granulometries of 5, 15, and 30 µm were obtained; the specific surface area was determined by laser diffraction; the topography was determined by scanning electron microcopy; and the particles were chemically analysed by X-ray energy microanalysis. The residual stresses of the particles were obtained by X-ray diffraction using the Bragg-Bentano configuration. The release of titanium ions to the physiological medium was performed using ICP-MS at 1, 3, 7, 14, and 21 days. The cytocompatibility of the particles with HFF-1 fibroblast and SAOS-2 osteoblast cultures was characterized. The results showed that the lowest specific surface area (0.2109 m2/g) corresponds to the particles larger than 30 µm being higher than 0.4969 and 0.4802 m2/g of those that are 5 and 15 µm, respectively, observing in all cases that the particles have irregular morphologies without contamination of the drills used in the surgery. The highest residual stresses were found for the small particles, −395 MPa for the 5 µm particles, and −369 for the 15 µm particles, and the lowest residual stresses were found for the 30 µm particles with values of −267 MPa. In all cases, the residual stresses were compressive. The lowest ion release was for the 30 µm samples, as they have the lowest specific surface area. Cytocompatibility studies showed that the particles are cytocompatible, but it is the smallest ones that are lower and very close to the 70% survival limit in both fibroblasts and osteoblasts. |
Cita | Callejas, J.A., Brizuela, A., Ríos Carrasco, B. y Gil, J. (2022). The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour. Materials, 15 (10), 3636. https://doi.org/10.3390/ma15103636. |
Ficheros | Tamaño | Formato | Ver | Descripción |
---|---|---|---|---|
The Characterizatiion of.pdf | 3.675Mb | [PDF] | Ver/ | |