Article
Experimental Validation of an Analytical Microdosimetric Model Based on Geant4-DNA Simulations by Using a Silicon-based Microdosimeter
Author/s | Bertolet, A.
Grilj, V. Guardiola, C. Harken, A. D. Cortés Giraldo, Miguel Antonio Baratto Roldán, A. Carabe, A. |
Department | Universidad de Sevilla. Departamento de Física Atómica, Molecular y Nuclear |
Publication Date | 2020 |
Deposit Date | 2023-02-23 |
Published in |
|
Abstract | Purpose: To study the agreement between proton microdosimetric distributions measured with a silicon-based cylindrical microdosimeter and a previously published analytical microdosimetric model based on Geant4-DNA in-water ... Purpose: To study the agreement between proton microdosimetric distributions measured with a silicon-based cylindrical microdosimeter and a previously published analytical microdosimetric model based on Geant4-DNA in-water Monte Carlo simulations for low energy proton beams. Methods and material: Distributions for lineal energy (y) are measured for four proton monoenergetic beams with nominal energies from 2.0 MeV to 4.5 MeV, with a tissue equivalent proportional counter (TEPC) and a silicon-based microdosimeter. The actual energy for protons traversing the silicon-based microdosimeter is simulated with SRIM. Monoenergetic beams with these energies are simulated with Geant4-DNA code by simulating a water cylinder site of dimensions equal to those of the microdosimeter. The microdosimeter response is calibrated by using the distribution peaks obtained from the TEPC. Analytical calculations for y‾F and y‾D using our methodology based on spherical sites are also performed choosing the equivalent sphere to be checked against experimental results. Results: Distributions for y at silicon are converted into tissue equivalent and compared to the Geant4-DNA simulated, yielding maximum deviations of 1.03% for y‾F and 1.17% for y‾D. Our analytical method generates maximum deviations of 1.29% and 3.33%, respectively, with respect to experimental results. Conclusion: Simulations in Geant4-DNA with ideal cylindrical sites in liquid water produce similar results to the measurements in an actual silicon-based cylindrical microdosimeter properly calibrated. The found agreement suggests the possibility to experimentally verify the calculated clinical y‾D with our analytical method. |
Funding agencies | National Institute of Biomedical Imaging and Bioengineering (NIBIB). USA European Union (UE) Gobierno de España |
Project ID. | 5P41 EB002033
745109 675265 RTI2018-098117-B-C21 |
Citation | Bertolet, A., Grilj, V., Guardiola, C., Harken, A.D., Cortés Giraldo, M.A., Baratto Roldán, A. y Carabe, A. (2020). Experimental Validation of an Analytical Microdosimetric Model Based on Geant4-DNA Simulations by Using a Silicon-based Microdosimeter. Radiation Physics and Chemistry, 176, 109060. https://doi.org/10.1016/j.radphyschem.2020.109060. |
Files | Size | Format | View | Description |
---|---|---|---|---|
Experimental validation of an ... | 1.421Mb | [PDF] | View/ | |