Mostrar el registro sencillo del ítem

Artículo

dc.creatorGonzález Martín, Javieres
dc.creatorGarcía Muñoz, Manueles
dc.creatorHerrmann, A.es
dc.creatorAyllón Guerola, Juan Manueles
dc.creatorGaldón Quiroga, Joaquínes
dc.creatorKovacsik, A.es
dc.creatorLeitenstern, P.es
dc.creatorLunt, T.es
dc.creatorRivero Rodríguez, Juan Franciscoes
dc.creatorSieglin, B.es
dc.creatorZoletnik, S.es
dc.creatorDomínguez Abascal, Jaimees
dc.date.accessioned2023-02-16T17:46:05Z
dc.date.available2023-02-16T17:46:05Z
dc.date.issued2019
dc.identifier.citationGonzález Martín, J., García Muñoz, M., Herrmann, A., Ayllón Guerola, J.M., Galdón Quiroga, J., Kovacsik, A.,...,Domínguez Abascal, J. (2019). First measurements of a magnetically driven fast-ion loss detector on ASDEX Upgrade. Journal of Instrumentation, 14 (11), C11005. https://doi.org/10.1088/1748-0221/14/11/C11005.
dc.identifier.issn1748-0221es
dc.identifier.urihttps://hdl.handle.net/11441/142756
dc.description.abstractA new scintillator-based fast-ion loss detector (FILD) has been deployed ∼45ˆ below the midplane of the ASDEX Upgrade tokamak. Port unavailability at this remote location requires an in-situ magnetically driven manipulator to move the diagnostic head horizontally through the scrape-off layer (SOL). The linear displacement is produced by an externally energized coil, whose magnetic dipole tries to align with the toroidal component of the tokamak magnetic field. The insertion is given by force balance between a retaining spring and the energized solenoid, whose current is regulated in real-time, opening the possibility of self-adaptive real-time control of the probe head location based on its temperature. The diagnostic head contains a scintillator screen, Faraday cup, thermocouple and collimator systems. The scintillator image is transferred to a vacuum window using a 3.5 meters quartz image guide. The light acquisition system is composed by a charge coupled device (CCD) camera, for high velocity-space resolution, and by an 8×4 channels avalanche photo diode (APD) camera, for high temporal resolution (up to 2 MHz). First measurements of magnetohydrodynamic (MHD) induced fast-ion losses and radially resolved fast-ion losses are presented.es
dc.description.sponsorshipComunidad Europea de Energía Atómica (EURATOM) 633053es
dc.description.sponsorshipMinisterio de Ciencia e Innovación FPU15/06074es
dc.formatapplication/pdfes
dc.format.extent8 p.es
dc.language.isoenges
dc.publisherInstitute of Physics Publishinges
dc.relation.ispartofJournal of Instrumentation, 14 (11), C11005.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectDetector design and construction technologies and materialses
dc.subjectPlasma diagnostics - probeses
dc.subjectScintillators, scintillation and light emission processes (solid, gas and liquid scintillators)es
dc.titleFirst measurements of a magnetically driven fast-ion loss detector on ASDEX Upgradees
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Mecánica y de Fabricaciónes
dc.relation.projectID633053es
dc.relation.projectIDFPU15/06074es
dc.relation.publisherversionhttps://doi.org/10.1088/1748-0221/14/11/C11005es
dc.identifier.doi10.1088/1748-0221/14/11/C11005es
dc.journaltitleJournal of Instrumentationes
dc.publication.volumen14es
dc.publication.issue11es
dc.publication.initialPageC11005es
dc.contributor.funderComunidad Europea de Energía Atómica (EURATOM)es
dc.contributor.funderMinisterio de Ciencia e Innovación (MICIN). Españaes

FicherosTamañoFormatoVerDescripción
First measurements.pdf789.6KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional