Show simple item record

Article

dc.creatorCapote Puente, Raúles
dc.creatorBautista Llamas, María Josées
dc.creatorManzoni, Caterinaes
dc.creatorSánchez González, José Maríaes
dc.date.accessioned2022-12-23T10:19:32Z
dc.date.available2022-12-23T10:19:32Z
dc.date.issued2022
dc.identifier.citationCapote Puente, R., Bautista Llamas, M.J., Manzoni, C. y Sánchez González, J.M. (2022). Pre-Lens Tear Meniscus Height, Lipid Layer Pattern and Non-Invasive Break-Up Time Short-Term Changes with a Water Gradient Silicone Hydrogel Contact Lens. Life, 12 (11), 1710. https://doi.org/10.3390/life12111710.
dc.identifier.issn2075-1729es
dc.identifier.urihttps://hdl.handle.net/11441/140799
dc.description.abstractTo evaluate pre-lens tear film volume, stability and lipid interferometry patterns with a silicone hydrogel water content contact lens, a novel, noninvasive, ocular-surface-analyzer technology was used. A prospective, longitudinal, single-center, self-control study was performed in daily or monthly replacement silicone hydrogel contact lens wearers. A tear film analysis was achieved with the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA) from SBM System. The subjects were reassessed, with the contact lens, after 30 min of wearing to quantify the volume, stability and lipid pattern of the short-term pre-lens tear film. Lipid layer thickness decreased from 2.05 ± 1.53 to 1.90 ± 1.73 Guillon patterns (p = 0.23). First pre-lens NIBUT decreased from 5.03 ± 1.04 to 4.63 ± 0.89 s (p = 0.01). Mean pre-lens NIBUT significantly increased from 15.19 ± 9.54 to 21.27 ± 11.97 s (p < 0.01). Lid opening time significantly increased from 26.36 ± 19.72 to 38.58 ± 21.78 s (p < 0.01). The silicone hydrogel contact lens with water gradient technology significantly increased the mean pre-lens NIBUT and lid opening time. Lehfilcon A suggested an improvement in contact lens wearers with tear film instability or decreased subjective symptoms of dry eye disease.es
dc.formatapplication/pdfes
dc.format.extent10 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofLife, 12 (11), 1710.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectpre-lens tear filmes
dc.subjectlipid patternes
dc.subjectnon-invasive break-up timees
dc.subjectcontact lenses
dc.titlePre-Lens Tear Meniscus Height, Lipid Layer Pattern and Non-Invasive Break-Up Time Short-Term Changes with a Water Gradient Silicone Hydrogel Contact Lenses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física de la Materia Condensadaes
dc.relation.publisherversionhttps://dx.doi.org/10.3390/life12111710es
dc.identifier.doi10.3390/life12111710es
dc.journaltitleLifees
dc.publication.volumen12es
dc.publication.issue11es
dc.publication.endPage1710es

FilesSizeFormatViewDescription
publife-12-01710.pdf1017.KbIcon   [PDF] View/Open  

This item appears in the following collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as: Attribution-NonCommercial-NoDerivatives 4.0 Internacional