Mostrar el registro sencillo del ítem

Trabajo Fin de Grado

dc.contributor.advisorBarragán-Villarejo, Manueles
dc.contributor.advisorMarano-Marcolini, Alejandroes
dc.creatorCarmona Marín, María del Vallees
dc.date.accessioned2022-12-19T18:49:52Z
dc.date.available2022-12-19T18:49:52Z
dc.date.issued2022
dc.identifier.citationCarmona Marín, M.d.V. (2022). Evaluación e Integración de una red híbrida en Optimal Power Flow. (Trabajo Fin de Grado Inédito). Universidad de Sevilla, Sevilla.
dc.identifier.urihttps://hdl.handle.net/11441/140653
dc.description.abstractEl siguiente trabajo de fin de grado consiste en el análisis de redes híbridas, entendiéndose como red híbrida a aquella red compuesta por circuitos de alterna y continua interconectados entre sí. Este análisis pretende poner el foco en la generación distribuida que tanto está apareciendo en los últimos años. El estudio parte de una red simple de 4 nudos con 4 periodos de tiempo hasta evolucionar a una red de mayor complejidad, red de 12 nudos con un perfil de potencia de 24 horas. Con este último paso, el estudio llega a una situación cercana al comportamiento actual de la sociedad. En ella se aprecian generaciones fotovoltaicas en puntos de consumo y cargas con comportamientos adaptados al tipo de consumo, ya sea hogar o laboral. Los dos objetivos de interés durante cada estudio es la reducción de pérdidas para conseguir así una red más eficiente. Durante la búsqueda del objetivo se comparan en todo momento tres situaciones de la red: 1. Situación con de la red sin batería. 2. Situación de la red incluyendo batería. 3. Situación de la red incluyendo batería y conexionado de esta con la red a través de una línea de continua. De tal manera, se pretende llegar una conclusión obtenidos los resultados de incluir la batería a través de una red de continua.es
dc.description.abstractThe following final degree work consists of the analysis of hybrid networks, understanding hybrid network as a network composed of alternating and direct circuits interconnected with each other. This analysis aims to focus on the distributed generation that has been appearing in recent years. The study starts with a simple 4-node network with 4 time periods and evolves to a more complex network, a 12-node network with a 24-hour power profile. With this last step, the study arrives at a situation close to the current behavior of society. It shows photovoltaic generations at points of consumption and loads with behaviors adapted to the type of consumption, whether at home or at work. The two objectives of interest during each study is the reduction of losses in order to achieve a more efficient network. During the pursuit of the objective, three network situations are compared at all times: 1. Network situation without battery. 2. Grid situation including battery. 3. Grid situation including battery and connection of the battery to the grid via a direct current line. In this way, it is intended to reach a conclusion obtained from the results of including the battery through a direct current network.es
dc.formatapplication/pdfes
dc.format.extent103 p.es
dc.language.isospaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleEvaluación e Integración de una red híbrida en Optimal Power Flowes
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Eléctricaes
dc.description.degreeUniversidad de Sevilla. Grado en Ingeniería de las Tecnologías Industrialeses

FicherosTamañoFormatoVerDescripción
TFG4342_Carmona Marin.pdf2.519MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional