dc.creator | González-Pena, Mariña | es |
dc.creator | Castro García, Juan Antonio | es |
dc.creator | Molina Cantero, Alberto Jesús | es |
dc.creator | Merino Monge, Manuel | es |
dc.creator | Gómez González, Isabel María | es |
dc.date.accessioned | 2022-05-20T09:35:59Z | |
dc.date.available | 2022-05-20T09:35:59Z | |
dc.date.issued | 2021-09 | |
dc.identifier.citation | González-Pena, M., Castro García, J.A., Molina Cantero, A.J., Merino Monge, M. y Gómez González, I.M. (2021). Study of Blood-Pressure Measurement Using Noninvasive Methods. Engineering Proceedings, 7 (1), 8-. | |
dc.identifier.issn | 2673-4591 | es |
dc.identifier.uri | https://hdl.handle.net/11441/133500 | |
dc.description.abstract | The correct diagnosis of high blood pressure is important to avoid cardiovascular diseases. In this work, we propose a low-cost noninvasive blood-pressure measurement unit composed of a photoplethysmograph and an electrocardiograph. It is based on pulse transit time measurement, thus performing nonocclusive measurement. To test the effectiveness of this parameter, a total of five subjects were measured, verifying their effectiveness at all times. | es |
dc.description.sponsorship | Spanish Ministry of Science and Innovation, State Plan 2017–2020 PID2019-104323RB-C32 | es |
dc.format | application/pdf | es |
dc.format.extent | 4 p. | es |
dc.language.iso | eng | es |
dc.publisher | MDPI | es |
dc.relation.ispartof | Engineering Proceedings, 7 (1), 8-. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Blood pressure | es |
dc.subject | PTT | es |
dc.subject | Pulse transit time | es |
dc.subject | PPG | es |
dc.subject | ECG | es |
dc.title | Study of Blood-Pressure Measurement Using Noninvasive Methods | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Tecnología Electrónica | es |
dc.relation.projectID | PID2019-104323RB-C32 | es |
dc.relation.publisherversion | https://www.mdpi.com/2673-4591/7/1/8 | es |
dc.identifier.doi | 10.3390/engproc2021007008 | es |
dc.contributor.group | Universidad de Sevilla. TIC022: Tecnologías para la Asistencia, la Integración y la Salud | es |
idus.validador.nota | This article belongs to the Proceedings of The 4th XoveTIC Conference | es |
dc.journaltitle | Engineering Proceedings | es |
dc.publication.volumen | 7 | es |
dc.publication.issue | 1 | es |
dc.publication.initialPage | 8 | es |