Mostrar el registro sencillo del ítem

Artículo

dc.creatorBlázquez-Hinarejos, Mónicaes
dc.creatorSaka-Herrán, Constanzaes
dc.creatorDíez-Alonso, Víctores
dc.creatorAyuso-Montero, Raúles
dc.creatorVelasco-Ortega, Eugenioes
dc.creatorLópez López, Josées
dc.date.accessioned2021-09-10T11:44:22Z
dc.date.available2021-09-10T11:44:22Z
dc.date.issued2021-04-12
dc.identifier.citationBlázquez-Hinarejos, M., Saka-Herrán, C., Díez-Alonso, V., Ayuso-Montero, R., Velasco-Ortega, E. y López López, J. (2021). Reliability and agreement of three devices for measuring implant stability quotient in the animal ex vivo model. Applied Sciences, 11 (8). https://doi.org/10.3390/app11083453.
dc.identifier.issn2076-3417es
dc.identifier.urihttps://hdl.handle.net/11441/125619
dc.description.abstractResonance frequency analysis (RFA) is the most extended method for measuring implant stability. The implant stability quotient (ISQ) is the measure obtained by different RFA devices; however, inter- and intra-rater reliability and agreement of these instruments remain unknown. Thirty implants were placed in three different pig mandibles. ISQ was measured parallel and perpendicular (lingual) to the peg axis with Osstell® Beacon, Penguin® and MegaISQ® by two different investigators and furthermore, one performed a test-retest. Intraclass correlation coefficient was calculated to assess the intra- and inter-rater reliability. Pearson correlation coefficient was used to assess the agreement. Intraclass correlation coefficients ranged from 0.20 to 0.65 for the Osstell® Beacon; 0.57 to 0.86 for the Penguin®; and −0.01 to 0.60 for the MegaISQ®. The highest ISQ values were obtained using Penguin® (66.3) in a parallel measurement; the lowest, using the MegaISQ® (60.1) in a parallel measurement. The highest correlation values with the other devices were obtained by MegaISQ® in a parallel measurement. Osstell® Beacon and MegaISQ® showed lower reliability than Penguin®. Osstell® had good agreement for measuring ISQ both in parallel and perpendicular, and MegaISQ® had the best agreement for measuring ISQ in paralleles
dc.description.sponsorshipBiohorizons-Camlog® Ibérica, 018582/2019es
dc.description.sponsorshipFacultad de Medicina y Ciencias de la Salud de la Universidad de Barcelona.es
dc.formatapplication/pdfes
dc.format.extent8 p.es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofApplied Sciences, 11 (8).
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectResonance frequency analysises
dc.subjectImplant stability quotientes
dc.subjectReliabilityes
dc.subjectAgreementes
dc.titleReliability and agreement of three devices for measuring implant stability quotient in the animal ex vivo modeles
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.projectID018582/2019es
dc.relation.publisherversionhttps://www.mdpi.com/2076-3417/11/8/3453es
dc.identifier.doi10.3390/app11083453es
dc.journaltitleApplied Scienceses
dc.publication.volumen11es
dc.publication.issue8es

FicherosTamañoFormatoVerDescripción
Reliability and agreement of ...2.597MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional