dc.creator | Blázquez-Hinarejos, Mónica | es |
dc.creator | Saka-Herrán, Constanza | es |
dc.creator | Díez-Alonso, Víctor | es |
dc.creator | Ayuso-Montero, Raúl | es |
dc.creator | Velasco-Ortega, Eugenio | es |
dc.creator | López López, José | es |
dc.date.accessioned | 2021-09-10T11:44:22Z | |
dc.date.available | 2021-09-10T11:44:22Z | |
dc.date.issued | 2021-04-12 | |
dc.identifier.citation | Blázquez-Hinarejos, M., Saka-Herrán, C., Díez-Alonso, V., Ayuso-Montero, R., Velasco-Ortega, E. y López López, J. (2021). Reliability and agreement of three devices for measuring implant stability quotient in the animal ex vivo model. Applied Sciences, 11 (8). https://doi.org/10.3390/app11083453. | |
dc.identifier.issn | 2076-3417 | es |
dc.identifier.uri | https://hdl.handle.net/11441/125619 | |
dc.description.abstract | Resonance frequency analysis (RFA) is the most extended method for measuring implant
stability. The implant stability quotient (ISQ) is the measure obtained by different RFA devices;
however, inter- and intra-rater reliability and agreement of these instruments remain unknown.
Thirty implants were placed in three different pig mandibles. ISQ was measured parallel and
perpendicular (lingual) to the peg axis with Osstell® Beacon, Penguin® and MegaISQ® by two
different investigators and furthermore, one performed a test-retest. Intraclass correlation coefficient
was calculated to assess the intra- and inter-rater reliability. Pearson correlation coefficient was used
to assess the agreement. Intraclass correlation coefficients ranged from 0.20 to 0.65 for the Osstell®
Beacon; 0.57 to 0.86 for the Penguin®; and −0.01 to 0.60 for the MegaISQ®. The highest ISQ values
were obtained using Penguin® (66.3) in a parallel measurement; the lowest, using the MegaISQ®
(60.1) in a parallel measurement. The highest correlation values with the other devices were obtained
by MegaISQ® in a parallel measurement. Osstell® Beacon and MegaISQ® showed lower reliability
than Penguin®. Osstell® had good agreement for measuring ISQ both in parallel and perpendicular,
and MegaISQ® had the best agreement for measuring ISQ in parallel | es |
dc.description.sponsorship | Biohorizons-Camlog® Ibérica, 018582/2019 | es |
dc.description.sponsorship | Facultad de Medicina y Ciencias de la Salud de la Universidad de Barcelona. | es |
dc.format | application/pdf | es |
dc.format.extent | 8 p. | es |
dc.language.iso | eng | es |
dc.publisher | MDPI | es |
dc.relation.ispartof | Applied Sciences, 11 (8). | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Resonance frequency analysis | es |
dc.subject | Implant stability quotient | es |
dc.subject | Reliability | es |
dc.subject | Agreement | es |
dc.title | Reliability and agreement of three devices for measuring implant stability quotient in the animal ex vivo model | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Estomatología | es |
dc.relation.projectID | 018582/2019 | es |
dc.relation.publisherversion | https://www.mdpi.com/2076-3417/11/8/3453 | es |
dc.identifier.doi | 10.3390/app11083453 | es |
dc.journaltitle | Applied Sciences | es |
dc.publication.volumen | 11 | es |
dc.publication.issue | 8 | es |