dc.contributor.advisor | Velázquez Alonso, David | es |
dc.creator | Fernández Ruiz de Terry, Jacobo | es |
dc.date.accessioned | 2021-07-06T15:54:58Z | |
dc.date.available | 2021-07-06T15:54:58Z | |
dc.date.issued | 2021 | |
dc.identifier.citation | Fernández Ruiz de Terry, J. (2021). Estudio de viabilidad de cogeneración en régimen aislado para un hotel de alta montaña. (Trabajo Fin de Grado Inédito). Universidad de Sevilla, Sevilla. | |
dc.identifier.uri | https://hdl.handle.net/11441/115258 | |
dc.description.abstract | En la actualidad, la eficiente generación y utilización de la energía es uno de los pilares fundamentales en el sector terciario. Las nuevas políticas encaminadas a un desarrollo sostenible en el marco ambiental provocan que las fuentes de energía primaria menos seguras y limpias empiecen a generar problemas económicos y legales. En esta línea, aparece la cogeneración, que se convierte en un actor principal en esta continua búsqueda del ahorro energético.
En una primera parte, se analizará detalladamente la demanda energética del hotel situado en alta montaña, el cual se encuentra totalmente aislado de cualquier red de distribución. Posteriormente, partiendo de lo anterior, se estudiará la posibilidad de implantar un equipo de cogeneración que consiga satisfacer la máxima demanda energética, ligado a una previa instalación de una Planta Satélite de Regasificación, que permita utilizar gas natural como combustible, reduciendo las emisiones de dióxido de carbono a la atmósfera.
Finalmente, una vez comprobada la viabilidad técnica del proyecto, se procederá a un análisis económico, que precederá a la descripción de las principales conclusiones extraídas tras la realización del mismo. | es |
dc.description.abstract | Nowadays, the efficient generation and use of energy is one of the essentials pillars in the tertiary
sector. The new policies aimed at sustainable development in the environmental framework, cause
economic and legal problems with the old energy sources. In this line, cogeneration appears, which
becomes a main actor in this continuous search for energy saving.
In the first part, the energy demand of the hotel located in the high mountains will be analyzed in detail,
which is totally isolated from any distribution network. Subsequently, based on the above, the
possibility of implementing a cogeneration equipment that manages to satisfy the maximum energy
demand will be studied, linked to a previous installation of a Satellite Regasification Plant, which
allows the use of natural gas as fuel, reducing dioxide emissions. carbon to the atmosphere.
Finally, once the technical viability of the project has been verified, an economic analysis will be
carried out, which will precede the description of the main conclusions drawn after its completion. | es |
dc.format | application/pdf | es |
dc.format.extent | 116 | es |
dc.language.iso | spa | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | Estudio de viabilidad de cogeneración en régimen aislado para un hotel de alta montaña | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Ingeniería Energética | es |
dc.description.degree | Universidad de Sevilla. Grado en Ingeniería de la Energía | es |
dc.publication.endPage | 96 p. | es |