dc.creator | Peón Avés, Eduardo | es |
dc.creator | Domínguez-Trujillo, Cristina | es |
dc.creator | Pérez, H. | es |
dc.creator | Galván, J.C. | es |
dc.creator | Rodríguez-Ortiz, José Antonio | es |
dc.creator | Pavón Palacio, Juan José | es |
dc.creator | Torres Hernández, Yadir | es |
dc.date.accessioned | 2021-06-18T15:11:34Z | |
dc.date.available | 2021-06-18T15:11:34Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Peón Avés, E., Domínguez-Trujillo, C., Pérez, H., Galván, J.C., Rodríguez-Ortiz, J.A., Pavón Palacio, J.J. y Torres Hernández, Y. (2017). Deposición sol-gel de hidroxiapatita bioactiva sobre titanio poroso. Revista Cubana de Investigaciones Biomédicas, 36 (1), 1-11. | |
dc.identifier.issn | ISSN 0864-0300 | es |
dc.identifier.uri | https://hdl.handle.net/11441/112498 | |
dc.description.abstract | Introducción: el titanio y algunas de sus aleaciones son considerados la mejor
opción para fabricar implantes permanentes, debido a sus excelentes propiedades
mecánicas y resistencia a la corrosión en el ambiente fisiológico, además de su buena
biocompatibilidad y osteointegración.
Objetivo: solucionar algunas de las limitaciones más significativas de los implantes
de titanio: fenómenos de fatiga y falla de la biointerfase.
Métodos: muestras de titanio qp grado IV con porosidad de 250-355 μm, fueron
obtenidas por la técnica de space-holder (50 % vol. NH4HCO 3, 800 MPa y 1250 ºC
durante 2 h en alto vacío), produciéndose buen balance entre rigidez y resistencia
mecánica del material. Detrás los sustratos de titanio poroso fueron recubiertos con
hidroxiapatita obtenida vía sol-gel, por inmersión, secadas a 80 ºC y tratadas
térmicamente a 450 ºC durante 5 h en vacío. La formación de fase, morfología de la
superficie, microestructura interfacial, capacidad de infiltración y sección transversal
de los recubrimientos, fue investigada por diferentes métodos de análisis químicofísico Resultados: los análisis de espectroscopia infrarroja de transformada de Fourier y
difracción de rayos X mostraron la cristalinidad de la fase y la homogeneidad en la
composición química del recubrimiento. La evaluación micromecánica y adherencia del
recubrimiento (curvas de P-h y resistencia al rayado) demostraron una buena
adherencia del recubrimiento al sustrato metálico. El recubrimiento fue poroso sin
evidencia de formación de grietas. Estos poros aparecen interconectados formando
una red continua, característica morfológica que es una ventaja para permitir la
circulación de fluido fisiológico, cuando se utiliza el sistema para aplicaciones
biomédicas.
Conclusiones: la cristalinidad satisfactoria y adhesión entre el recubrimiento y el
sustrato sugieren el sistema como promisorio para aplicaciones en el desarrollo de
implantes ortopédicos. | es |
dc.description.abstract | Introduction: Titanium and some titanium alloys are considered to be the best
materials for permanent implants, due to their excellent mechanical properties and
resistance to corrosion in physiological environments, as well as their good
biocompatibility and osseointegration. Objective: Solve some of the most significant
limitations of titanium implants: fatigue phenomena and biointerface failure.
Methods: Samples of cp titanium grade 4 with a porosity of 250-355 μm were
obtained by space-holder technique (50 % vol. NH4HCO3 , 800 MPa and 1250 ºC for 2
h in high vacuum), achieving a good balance between rigidity and mechanical
resistance of the material. The porous titanium substrates were then covered with
hydroxyapatite obtained via sol-gel immersion, dried at 80 ºC and thermally treated
at 450 ºC for 5 h in a vacuum. Phase formation, surface morphology, interfacial
microstructure, infiltration capacity and cross-section of coatings, were assessed with
various physicochemical analysis methods.
Results: Fourier transform infrared spectroscopy and X-ray diffraction analysis
showed the crystallinity of the phase and the homogeneity in the chemical
composition of the coating. Micromechanical evaluation and coating adherence (P-h
curves and scratch resistance) revealed good adherence of the coating to the metallic
substrate. The coating was found to be porous without any evidence of crack
formation. The pores seem to be interconnected into a continuous network, a
morphological characteristic enabling circulation of physiological fluid when the
system is used for biomedical applications.
Conclusions: Satisfactory crystallinity and adhesion between the coating and the
substrate suggest that the system is promising for application in the development of
orthopedic implants. | es |
dc.format | application/pdf | es |
dc.format.extent | 11 p. | es |
dc.language.iso | spa | es |
dc.publisher | ECIMED | es |
dc.relation.ispartof | Revista Cubana de Investigaciones Biomédicas, 36 (1), 1-11. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Hidroxiapatita | es |
dc.subject | Titanio | es |
dc.subject | Sol-gel | es |
dc.subject | Tamaño de poro | es |
dc.subject | Hydroxyapatite | es |
dc.subject | Titanium | es |
dc.subject | Pore size | es |
dc.title | Deposición sol-gel de hidroxiapatita bioactiva sobre titanio poroso | es |
dc.title.alternative | Sol-gel deposition of bioactive hydroxyapatite on porous titanium | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Ingeniería y Ciencia de los Materiales y del Transporte | es |
dc.relation.publisherversion | http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-03002017000100007&lng=en&nrm=iso&tlng=es | es |
dc.journaltitle | Revista Cubana de Investigaciones Biomédicas | es |
dc.publication.volumen | 36 | es |
dc.publication.issue | 1 | es |
dc.publication.initialPage | 1 | es |
dc.publication.endPage | 11 | es |
dc.identifier.sisius | 21584597 | es |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es |
dc.contributor.funder | Junta de Andalucía | es |
dc.contributor.funder | European Commission (EC). Fondo Europeo de Desarrollo Regional (FEDER) | es |