dc.description.abstract | Introducción: La toma de moldes se respalda en la actualidad en técnicas basadas más en la
experiencia y la subjetividad del técnico que en la objetividad del procedimiento. El objetivo
de este estudio fue demostrar la eficacia de una técnica de toma de molde del pie en carga
controlada mediantes sensores de presión. De esta forma se pretende objetivar el grado de
corrección.
Material y método: El estudio piloto se realizó sobre 15 pies de 9 sujetos con pies pronados,
a los que se les calculó el valor del índice de simetría del talón y se valoró la diferencia de
altura entre cabeza de 1.◦ y 5.◦ metatarsianos. Para ello se tomaron 3 moldes en 3 situaciones
distintas en un mismo pie: un primer molde al que al sujeto no se le controló la posición del pie,
otro segundo molde en el que se hicieron las manipulaciones para corregir la posición pronada
del mismo, y un tercer molde al que se le colocaron previamente sensores de presión en el
talón y metatarso, lo que permitió controlar y cuantificar la presión durante la manipulación
en el proceso de la toma de molde.
Resultados: La comparación del índice de simetría del talón en los diferentes grupos mostró valores significativos de una p de 0,001. Igualmente la comparación de la diferencia de
altura entre cabeza 1.◦
-5.◦ metatarsianos en ambos grupos también mostró valores de p < 0,001,
diferentes en las distintas técnicas de toma de molde.
Conclusión: En conclusión, la técnica de toma de molde controlada con sensores de presión
consiguió la obtención de moldes más equilibrados, con mejor simetría del contorno del talón
y menor diferencia de altura entre el 1.◦ y 5.◦ metatarsianos. | es |
dc.description.abstract | Introduction: Foot casting is essential in orthotic treatments. Several materials and procedures
are involved in this process. There is no evidence of the reliability of casting techniques, as
these procedures are based on the subjectivity of the podiatrist more than objective references.
The aim of this study was to demonstrate the efficacy of a foot casting technique using plantar
pressure sensors.
Material and method: The study was conducted on 9 people with 15 pronated feet (FPI > 6).
A total of 3 types of foot weight-bearing casting were taken (relaxed position, controlled
position, and controlled position using load sensors). The Heel Symmetry Index and 1st-5th
metatarsal head height difference was calculated and compared in the 3 types.
Results: The comparison of Heel Symmetry Index in the different groups showed significant
differences (P = .001). The 1st-5th metatarsal head height difference variable showed values of
P < .001 in the different groups.
Conclusion: Foot casting by controlled plantar sensors achieved a more balanced cast with
greater heel symmetry, and less difference in the 1st-5th metatarsal head heights | es |
dc.format | application/pdf | es |
dc.format.extent | 52 | es |
dc.language.iso | spa | es |
dc.publisher | Elsevier | es |
dc.relation.ispartof | Revista Española De Podología, 27 (2), 7 p.-46. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Pie plano | es |
dc.subject | Ortesis del pie | es |
dc.subject | Subastragalina neutra | es |
dc.subject | Plantilla | es |
dc.subject | Flatfoot | es |
dc.subject | Foot orthoses | es |
dc.subject | Subtalar | es |
dc.subject | Insole | es |
dc.title | Toma de molde en carga con control de presiones en pies pronados | es |
dc.title.alternative | Weight-bearing castings with pressure control in pronated feet | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Podología | es |
dc.relation.publisherversion | https://www.elsevier.es/es-revista-revista-espanola-podologia-224-pdf-S0210123816300329 | es |
dc.identifier.doi | 10.1016/j.repod.2016.09.0010210-1238 | es |
dc.journaltitle | Revista Española De Podología | es |
dc.publication.volumen | 27 | es |
dc.publication.issue | 2 | es |
dc.publication.initialPage | 7 p. | es |
dc.publication.endPage | 46 | es |