dc.creator | Rando, Enrique | es |
dc.creator | Pérez García, Pablo | es |
dc.creator | Huertas Sánchez, Gloria | es |
dc.creator | Yúfera García, Alberto | es |
dc.date.accessioned | 2021-03-25T08:49:26Z | |
dc.date.available | 2021-03-25T08:49:26Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Rando, E., Pérez García, P., Huertas Sánchez, G. y Yúfera García, A. (2019). A plethysmographic sensor for monitoring volume changes in cardiovascular pathologies. En DCIS 2019: Conference on Design of Circuits and Integrated Circuits Bilbao, España: IEEE Computer Society. | |
dc.identifier.isbn | 978-1-7281-5458-9 | es |
dc.identifier.issn | 2640-5563 | es |
dc.identifier.uri | https://hdl.handle.net/11441/106613 | |
dc.description.abstract | This paper presents a capacitive system capable
of performing leg volume change monitorization in patients
suffering from Heart Failure (HF) conditions. The body volume
evolution serves as a prognosis marker for this kind of patients,
such patients can benefit from a wearable monitorization system.
The proposal is based on a contactless capacitive wearable
structure implemented by a two-plate plane-parallel capacitor
geometry. The system exhibits sensitivity to leg volume change
and the sensor curves are provided. A 2.5x2.5cm capacitive
electrode design will generate capacitive values within the range
[1-2] pF. Acquisition of the capacitance value is performed via an
electronic differentiator implemented using op-amps, illustrating
good results in simulated volume analysis implemented using
pspice. | es |
dc.description.sponsorship | Ministerio de Ciencia, Innovación y Universidades RTI2018-093512-B-C21 | es |
dc.format | application/pdf | es |
dc.format.extent | 6 | es |
dc.language.iso | eng | es |
dc.publisher | IEEE Computer Society | es |
dc.relation.ispartof | DCIS 2019: Conference on Design of Circuits and Integrated Circuits (2019). | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | A plethysmographic sensor for monitoring volume changes in cardiovascular pathologies | es |
dc.type | info:eu-repo/semantics/conferenceObject | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/submittedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Tecnología Electrónica | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Electrónica y Electromagnetismo | es |
dc.relation.projectID | RTI2018-093512-B-C21 | es |
dc.relation.publisherversion | https://ieeexplore.ieee.org/document/8959885 | es |
dc.identifier.doi | 10.1109/DCIS201949030.2019.8959885 | es |
dc.eventtitle | DCIS 2019: Conference on Design of Circuits and Integrated Circuits | es |
dc.eventinstitution | Bilbao, España | es |
dc.relation.publicationplace | New York, USA | es |
dc.contributor.funder | Ministerio de Ciencia, Innovación y Universidades (MICINN). España | es |