Mostrar el registro sencillo del ítem

Trabajo Fin de Grado

dc.contributor.advisorGuzmán-Miranda, Hipólitoes
dc.contributor.advisorBarriga-Rivera, Alejandroes
dc.creatorJiménez Fernández, Pabloes
dc.date.accessioned2019-06-10T17:07:31Z
dc.date.available2019-06-10T17:07:31Z
dc.date.issued2019
dc.identifier.citationJiménez Fernández, P. (2019). Neuroestimulador de ondas arbitrarias. (Trabajo Fin de Grado Inédito). Universidad de Sevilla, Sevilla.
dc.identifier.urihttps://hdl.handle.net/11441/87300
dc.description.abstractUn neuroestimulador es un dispositivo médico capaz de suministrar corriente controlada al tejido excitable objetivo. Al hacerlo, se puede lograr la modulación de la actividad del sistema nervioso. La técnica habitual más empleada se basa en el envío de pulsos de carga bifásica y balanceada. Este método permite la entrega y recogida de la misma cantidad de carga eléctrica, evitando dañar el tejido sobre el que se aplican los estímulos y ralentizar la degradación de los electrodos. El objetivo de este diseño es fabricar un estimulador neuronal que pueda usarse en estudios preclínicos de forma segura. El estimulador neuronal proporcionará capacidades para estimular simultáneamente al menos a través de dos canales independientes. Este dispositivo debe ser programable y capaz de entregar las formas de onda de estímulo deseadas a la llegada de una señal de disparo. El sistema estará eléctricamente aislado de la fuente de alimentación por seguridad eléctrica. La corriente inyectada debe ser precisa y capaz de proporcionar formas de onda de al menos 30 kHz. Este dispositivo eventualmente ayudará a la investigación de nuevos paradigmas de estimulación que contribuyan, entre otros, a mejorar el rendimiento actual del ojo biónico.es
dc.description.abstractA neurostimulator is a medical device capable of delivering controlled current to target excitable tissue. By doing so, modulation of the activity of the nervous system can be achieved. The most commonly used technique is based on sending biphasic and balanced load pulses. This method allows the delivery and collection of the same amount of electrical charge, avoiding damaging the tissue on which the stimuli are applied and slowing down the degradation of the electrodes. The aim of this design is to create a neuronal stimulator that can be safely used in preclinical studies. The neural stimulator will provide the ability to stimulate simultaneously through at least two independent channels. This device must be programmable and capable of delivering the desired stimulus waveforms at the arrival of a trigger signal. The system will be electrically isolated from the power supply for electrical safety. The injected current must be accurate and capable of providing waveforms of at least 30 kHz. This device will eventually help the investigation of new stimulation paradigms that contribute, among others, to improve the current performance of the bionic eye.es
dc.formatapplication/pdfes
dc.language.isospaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleNeuroestimulador de ondas arbitrariases
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Electrónicaes
dc.description.degreeUniversidad de Sevilla. Grado en Ingeniería de Tecnologías Industrialeses
idus.format.extent67 p.es

FicherosTamañoFormatoVerDescripción
TFG-2241-JIMENEZ .pdf3.803MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional