Buscar
Mostrando ítems 11-20 de 35
Ponencia
Neutron capture cross section measurements at n_TOF of Np-237, Pu-240 and Am-243 for the transmutation of nuclear waste
(AIP Publishing, 2006)
Accurate and reliable neutron capture cross section data for actinides are necessary for the proper design, safety regulation and precise performance assessment of transmutation devices such as Fast Critical Reactors or ...
Artículo
Neutron-induced fission cross section of Np 237 in the keV to MeV range at the CERN n-TOF facility
(American Physical Society, 2016)
The neutron-induced fission cross section of 237 Np was experimentally determined at the high-resolution and high-intensity facility n TOF , at CERN, in the energy range 100 keV to 9 MeV, using the 235 U ( n,f ...
Ponencia
Measurement of La-139(n,gamma) cross section at n_TOF
(American Institute of Physics, 2006)
The capture cross section of the 139La has been measured relative to 197Au standard at n_TOF. We provide here a short description of the experimental apparatus and of the data analysis procedures. The extracted resonance ...
Artículo
Measurement of the radiative neutron capture cross section of 206 Pb and its astrophysical implications
(The American Physical Society, 2007)
The (n,γ) cross section of 206Pb has been measured at the CERN n_TOF facility with high resolution in the energy range from 1 eV to 620 keV by using two optimized 6C6D detectors. In the investigated energy interval about ...
Artículo
Measurement and analysis of the 243 Am neutron capture cross section at the n_TOF facility at CERN
(American Physical Society, 2014)
Background: The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Improvement of the Am243(n,γ) cross section uncertainty. ...
Artículo
Resonance neutron-capture cross sections of stable magnesium isotopes and their astrophysical implications
(American Physical Society, 2012)
We have measured the neutron capture cross sections of the stable magnesium isotopes 24 ,25 ,26Mg in the energy range of interest to the s process using the neutron time-of-flight facility n-TOF at CERN. Capture events ...
Artículo
Neutron physics of the Re/Os clock. I. Measurement of the (n, γ) cross sections of 186, 187, 188 Os at the CERN n_TOF facility
(The American Physical Society, 2010)
The precise determination of the neutron capture cross sections of 186Os and 187Os is important to define the s-process abundance of 187Os at the formation of the solar system. This quantity can be used to evaluate the ...
Artículo
Neutron capture cross section of 90Zr: Bottleneck in the s-process reaction flow
(The American Physical Society, 2008)
The neutron capture cross sections of the Zr isotopes have important implications in nuclear astrophysics and for reactor design. The small cross section of the neutron magic nucleus 90Zr, which accounts for more than 50% ...
Ponencia
Measurement of capture cross sections of 90,91,92,94,96Zr isotopes at n_TOF
(AIP Publishing, 2005)
The neutron capture cross sections for Zr isotopes have important implications in nuclear technologies as well in the field of nuclear astrophysics. The innovative features of the n_TOF CERN facility allowed for an accurate ...
Artículo
Measurement and resonance analysis of the 237Np neutron capture cross section
(American Physical Society, 2012)
The neutron capture cross section of 237Np was measured between 0.7 and 500 eV at the CERN n-TOF facility using the 4π BaF2 Total Absorption Calorimeter. The experimental capture yield was extracted minimizing all the ...