dc.identifier.citationRodríguez Martos, R., Torres-Lagares, D., Castellanos Cosano, L., Serrera Figallo, M.d.l.Á., Segura Egea, J.J. y Gutiérrez Pérez, J.L. (2012). Evaluation of apical preparations performed with ultrasonic diamond and stainless steel tips at different intensities using a scanning electron microscope in endodontic surgery. Medicina Oral, Patología Oral y Cirugía Bucal, 17 (6), e987-e993.
dc.identifier.issn1698-4447es
dc.identifier.urihttps://hdl.handle.net/11441/99319
dc.description.abstractObjective: The objective of our study is to analyse (with the help of scanning electron microscopes) the quality of the dental root surface and the appearance of dental cracks after performing apical preparations using two different types of ultrasonic tips. Study design: We used 32 single-rooted teeth that underwent a root canal and apical resection. Afterwards, the teeth were divided into 4 groups of 8 teeth each, with preparations of the apical cavities in the following manner: Group 1: stainless steel ultrasonic tip at 33 KHz. Group 2: stainless steel ultrasonic tip at 30 KHz. Group 3: diamond ultrasonic tip at 30 KHz. Group 4: diamond ultrasonic tip at 33 KHz. The quality of the root surface and the presence of cracks were evaluated by one single observer using a scanning electron microscope. Results: All of the teeth in our study had cracks after the apical preparations. The mean number of cracks per tooth ranged between 6. ± 1.9 (group 1) and 3.5 ± 2.4 (group 4), with a significantly higher number found in the groups that used stainless steel tips (P=.03). The types of cracks produced involved: 8 complete cracks (4.5%), 167 incomplete cracks (94.4%), and 2 intradentinal cracks (1.1%), with no significant differences observed between the different frequencies used for each group. Conclusions: Stainless steel ultrasonic tips provoked a larger number of cracks than diamond tips. The frequency of vibration used did not have any effect on the number of cracks found.es
dc.formatapplication/pdfes
dc.format.extent6es
dc.language.isoenges
dc.publisherMedicina Orales
dc.relation.ispartofMedicina Oral, Patología Oral y Cirugía Bucal, 17 (6), e987-e993.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectApicoectomyes
dc.subjectScanning electron microscopees
dc.subjectTherapeutic ultrasoundes
dc.subjectTherapeutic ultrasoundes
dc.subjectDentinal crackes
dc.titleEvaluation of apical preparations performed with ultrasonic diamond and stainless steel tips at different intensities using a scanning electron microscope in endodontic surgeryes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.publisherversionhttp://dx.doi.org/doi:10.4317/medoral.17961es
dc.identifier.doi10.4317/medoral.17961es
dc.journaltitleMedicina Oral, Patología Oral y Cirugía Bucales
dc.publication.volumen17es
dc.publication.issue6es
dc.publication.initialPagee987es
dc.publication.endPagee993es

FicherosTamañoFormatoVerDescripción
medoral-17-e988.pdf449.4KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional