dc.identifier.citationGranado Romero, J., Torralba Silgado, A.J. y Álvarez-Arroyo, C. (2018). Partial discharge detection using PLC receivers in MV cables: A theoretical framework. Electric Power Systems Research, 164, 61-69.
dc.identifier.issn0378-7796es
dc.identifier.urihttps://hdl.handle.net/11441/99001
dc.description.abstractPartial discharge (PD) activity is a key indicator of the cable insulation health in medium-voltage networks. Many of these cables are used as transmission media, because power line communication (PLC) modems are installed at their ends. This paper proposes two techniques that allow broadband PLC receivers to detect PDs at the same time that the PLC signal is being demodulated. The proposed techniques are based on how PDs alter both, null, and zero-bit loaded carriers, commonly used in orthogonal frequency division multiplexing modems. Using the proposed techniques, a simple firmware modification is sufficient to add this new functionality to the already installed modems. This paper is mainly concerned with theoretical aspects of the proposed techniques, and no experimental validation has been done. Nevertheless, simulation results show that the proposed techniques can be used to detect different types of PDs. Four cases studies are analyzed: short- and long-distance PDs, and low- and high-energy PDs. Finally, the impact of the inter-carrier interference on the detection capability is studied, and some recommendations are made to mitigate its effects.es
dc.formatapplication/pdfes
dc.format.extent9 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofElectric Power Systems Research, 164, 61-69.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectPartial dischargeses
dc.subjectPower line communication (PLC)es
dc.subjectMedium-voltage distribution cableses
dc.titlePartial discharge detection using PLC receivers in MV cables: A theoretical frameworkes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Electrónicaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Eléctricaes
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/abs/pii/S0378779618302232?via%3Dihubes
dc.identifier.doihttps://doi.org/10.1016/j.epsr.2018.07.030es
dc.contributor.groupUniversidad de Sevilla. TIC192: Ingeniería electrónicaes
dc.contributor.groupUniversidad de Sevilla. TEP175: Ingeniería eléctricaes
idus.validador.notaElsevier no ofrece periodo de tiempo de embargo para los postprint de artículos publicados en la revista Electric Power Systems Research.es
dc.journaltitleElectric Power Systems Researches
dc.publication.volumen164es
dc.publication.initialPage61es
dc.publication.endPage69es

FicherosTamañoFormatoVerDescripción
main.pdf577.9KbIcon   [PDF] Ver/Abrir   Artículo principal

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional