Mostrar el registro sencillo del ítem

Artículo

dc.creatorAlfaro Juárez, Asunciónes
dc.creatorCaro Magdaleno, Manueles
dc.creatorMontero Iruzubieta, Jesúses
dc.creatorFernández Palacín, Anaes
dc.creatorMuñoz Morales, Anaes
dc.creatorCastilla Martino, Manuel Albertoes
dc.creatorRodríguez de la Rúa Franch, Enriquees
dc.date.accessioned2020-04-28T12:52:00Z
dc.date.available2020-04-28T12:52:00Z
dc.date.issued2019-10-16
dc.identifier.citationAlfaro Juárez, A., Caro Magdaleno, M., Montero Iruzubieta, J., Fernández Palacín, A., Muñoz Morales, A., Castilla Martino, M.A. y Rodríguez de la Rúa Franch, E. (2019). Keratograph 5M As A Useful And Objective Tool For Evaluating The Ocular Surface In Limbal Stem Cell Deficiency.. Clinical Opthalmology, 13, 2025-2033.
dc.identifier.issn1177-5483es
dc.identifier.urihttps://hdl.handle.net/11441/95896
dc.description.abstractPurpose: In limbal stem cell deficiency, both the Ocular Surface Disease Index (OSDI) questionnaire and tear break-up time (BUT) are comparable between traditional methods and the Keratograph 5M. In this study, we aimed to correlate OSDI with Keratograph 5M interviewed OSDI, as well as slit-lamp tear BUT with Keratograph 5M noninvasive tear break-up time (NIKBUT) in limbal stem cell deficiency. Patients and methods: Thirty-eight limbal stem cell-deficiency patients (76 eyes) from Virgen Macarena-Rocio Hospital (Seville, Spain) underwent this diagnostic test study. All patients completed the traditional OSDI. We measured the BUT, performed a Keratograph 5M analysis of NIKBUT first (employed for the analysis) followed by the average NIKBUT, the level of dryness, and conducted the OSDI questionnaire through an interview. For each pair of tests, we analyzed the means and applied an intraclass correlation coefficient (r), creating a Bland-Altman plot for data dispersion. Results: Average values were 47.5 points (±25.8), and 47.3 points (±27.5) for traditional OSDI and Keratograph OSDI, respectively (P =0.87); the r value indicates good agreement (0.72). The Bland-Altman plot followed a linear pattern, and the results were similarly distributed. The NIKBUT mean was shorter than the BUT mean (P = 0.007); the r value indicates moderate agreement (0.574). The Bland-Altman plot formed an almost horizontal line, with almost all values between the mean and two standard deviations. Conclusion: Keratograph 5M is useful for the evaluation of the ocular surface in limbal stem cell deficiency. NIKBUT can substitute BUT based on its advantages of being non- invasive, objective, with intraobserver and interobserver repeatability and reliability. The Keratograph 5M OSDI is comparable to the traditional questionnaire.es
dc.description.sponsorshipUnión Europea RD16/0008/0010es
dc.formatapplication/pdfes
dc.format.extent9es
dc.language.isoenges
dc.relation.ispartofClinical Opthalmology, 13, 2025-2033.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectKeratographes
dc.subjectLimbal stem cell deficiencyes
dc.subjectNoninvasive keratograph tear break-up timees
dc.subjectOcular surface desease indexes
dc.subjectTear break-up time.es
dc.titleKeratograph 5M As A Useful And Objective Tool For Evaluating The Ocular Surface In Limbal Stem Cell Deficiency.es
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Cirugíaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Medicina Preventiva y Salud Públicaes
dc.identifier.doi10.2147/OPTH.S218313es
dc.contributor.groupUniversidad de Sevilla. CTS312: Análisis de la demanda sanitaria.es
dc.journaltitleClinical Opthalmologyes
dc.publication.volumen13es
dc.publication.initialPage2025es
dc.publication.endPage2033es

FicherosTamañoFormatoVerDescripción
Keratograph 5M As A Useful.pdf3.431MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional