dc.creator | Guardiola, C. | es |
dc.creator | Quirion, D. | es |
dc.creator | Pellegrini, G. | es |
dc.creator | Fleta, C. | es |
dc.creator | Esteban, S. | es |
dc.creator | Cortés Giraldo, Miguel Antonio | es |
dc.creator | Gómez, F. | es |
dc.creator | Solberg, T. | es |
dc.creator | Carabe, A. | es |
dc.creator | Lozano, M. | es |
dc.date.accessioned | 2020-04-15T08:50:11Z | |
dc.date.available | 2020-04-15T08:50:11Z | |
dc.date.issued | 2015 | |
dc.identifier.citation | Guardiola, C., Quirion, D., Pellegrini, G., Fleta, C., Esteban, S., Cortés Giraldo, M.A.,...,Lozano, M. (2015). Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy. Applied Physics Letters, 107 (2), 023505. | |
dc.identifier.issn | 0003-6951(impreso) | es |
dc.identifier.issn | 1077-3118 (electrónico) | es |
dc.identifier.uri | https://hdl.handle.net/11441/95213 | |
dc.description.abstract | In this work, we propose a solid-state-detector for use in radiation microdosimetry. This device improves the performance of existing dosimeters using customized 3D-cylindrical microstructures etched inside silicon. The microdosimeter consists of an array of micro-sensors that have 3D-cylindrical electrodes of 15 μm diameter and a depth of 5 μm within a silicon membrane, resulting in a well-defined micrometric radiation sensitive volume. These microdetectors have been characterized using an 241Am source to assess their performance as radiation detectors in a high-LET environment. This letter demonstrates the capability of this microdetector to be used to measure dose and LET in hadrontherapy centers for treatment plan verification as part of their patient-specific quality control program. | es |
dc.format | application/pdf | es |
dc.format.extent | 6 P. | es |
dc.language.iso | eng | es |
dc.publisher | AIP Publishing | es |
dc.relation.ispartof | Applied Physics Letters, 107 (2), 023505. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.title | Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física Atómica, Molecular y Nuclear | es |
dc.relation.publisherversion | http://dx.doi.org/10.1063/1.4926962 | es |
dc.identifier.doi | 10.1063/1.4926962 | es |
dc.journaltitle | Applied Physics Letters | es |
dc.publication.volumen | 107 | es |
dc.publication.issue | 2 | es |
dc.publication.endPage | 023505 | es |