dc.identifier.citationPino Lucena, F.J., Caro, R., Rosa Iglesias, M.F. y Guerra Macho, J.J. (2013). Experimental validation of an optical and thermal model of a linear Fresnel collector system. Applied Thermal Engineering, 50 (2), 1463-1471.
dc.identifier.issn1359-4311es
dc.identifier.urihttps://hdl.handle.net/11441/92741
dc.description2nd European Conference on Polygeneration – 30th March 1st April, 2011– Tarragona, Spaines
dc.description.abstractThis paper describes the design and validation of a mathematical model for a solar Fresnel collector. The function of the model is to simulate the optical and thermal dynamics of a Fresnel system for heating water. The model is validated using real data gathered from a cooling plant with double effect absorption chiller located in the School of Engineering University of Seville, Spain (Experimental cooling plant is also described in the paper). Comparison of calculated and plant measured data shows that the error is lower than 3% in the optical model and within 7% in the thermal model. The model uses a new approach to include a solar tracking mirror mechanism in one axis. This tracking has been designed to maximise the reception of available solar radiation by the absorption pipe. The thermal model used is based around classical models for solar receivers and it is validated with real operating data gathered from a supervisor system. The Fresnel model has been designed with sufficient flexibility to consider different geometries and thermal parameters, and may be used to simulate the performance of a proposed Fresnel collector system at any location.es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofApplied Thermal Engineering, 50 (2), 1463-1471.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFresnel collectores
dc.subjectOptical modeles
dc.subjectThermal modeles
dc.titleExperimental validation of an optical and thermal model of a linear Fresnel collector systemes
dc.title.alternativeExperimental validation of an optical and thermal model of a Linear Fresnel Collectores
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/submittedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Energéticaes
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S1359431111007174#!es
dc.identifier.doi10.1016/j.applthermaleng.2011.12.020es
dc.contributor.groupUniversidad de Sevilla. TEP143: Termotecniaes
idus.format.extent9 p.es
dc.journaltitleApplied Thermal Engineeringes
dc.publication.volumen50es
dc.publication.issue2es
dc.publication.initialPage1463es
dc.publication.endPage1471es
dc.identifier.sisius20048856es

FicherosTamañoFormatoVerDescripción
abs-22-francisco-javier-pino.pdf737.7KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional