Mostrar el registro sencillo del ítem

Artículo

dc.creatorAcosta García, Ignacio Javieres
dc.creatorCampano, Miguel Ángeles
dc.creatorDomínguez Amarillo, Samueles
dc.creatorMuñoz González, Carmen Maríaes
dc.date.accessioned2019-08-21T07:23:16Z
dc.date.available2019-08-21T07:23:16Z
dc.date.issued2018-11
dc.identifier.citationAcosta García, I.J., Campano, M.Á., Domínguez Amarillo, S. y Muñoz González, C.M. (2018). Dynamic Daylight Metrics for Electricity Savings in Offices: Window Size and Climate Smart Lighting Management. Energies, 11 (11), 3143-.
dc.identifier.issn1996-1073es
dc.identifier.urihttps://hdl.handle.net/11441/88476
dc.description.abstractDaylight performance metrics provide a promising approach for the design and optimization of lighting strategies in buildings and their management. Smart controls for electric lighting can reduce power consumption and promote visual comfort using different control strategies, based on affordable technologies and low building impact. The aim of this research is to assess the energy efficiency of these smart controls by means of dynamic daylight performance metrics, to determine suitable solutions based on the geometry of the architecture and the weather conditions. The analysis considers different room dimensions, with variable window size and two mean surface reflectance values. DaySim 3.1 lighting software provides the simulations for the study, determining the necessary quantification of dynamic metrics to evaluate the usefulness of the proposed smart controls and their impact on energy efficiency. The validation of dynamic metrics is carried out by monitoring a mesh of illuminance-meters in test cells throughout one year. The results showed that, for most rooms more than 3.00 m deep, smart controls achieve worthwhile energy savings and a low payback period, regardless of weather conditions and for worst-case situations. It is also concluded that dimming systems provide a higher net present value and allow the use of smaller window size than other control solutions.es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofEnergies, 11 (11), 3143-.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectDaylight autonomyes
dc.subjectwindow designes
dc.subjectenergy savinges
dc.subjectsmart controles
dc.titleDynamic Daylight Metrics for Electricity Savings in Offices: Window Size and Climate Smart Lighting Managementes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas I (ETSA)es
dc.identifier.doi10.3390/en11113143es
idus.format.extent27es
dc.journaltitleEnergieses
dc.publication.volumen11es
dc.publication.issue11es
dc.publication.initialPage3143es

FicherosTamañoFormatoVerDescripción
energies-11-03143-v2.pdf3.307MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional