Mostrar el registro sencillo del ítem

Ponencia

dc.creatorPérez Carrasco, José Antonioes
dc.creatorAcha Piñero, Begoñaes
dc.creatorSerrano Gotarredona, María del Carmenes
dc.date.accessioned2019-01-18T19:08:24Z
dc.date.available2019-01-18T19:08:24Z
dc.date.issued2015
dc.identifier.citationPérez Carrasco, J.A., Acha Piñero, B. y Serrano Gotarredona, M.d.C. (2015). Segmentation of bone structures in 3D CT images based on continuous max- ow optimization. En SPIE. Photonics West (94133Y-1-94133Y-6), San Francisco: Society of Photo-optical Instrumentation Engineers (SPIE).
dc.identifier.issn2329-4310es
dc.identifier.urihttps://hdl.handle.net/11441/81749
dc.description.abstractIn this paper an algorithm to carry out the automatic segmentation of bone structures in 3D CT images has been implemented. Automatic segmentation of bone structures is of special interest for radiologists and surgeons to analyze bone diseases or to plan some surgical interventions. This task is very complicated as bones usually present intensities overlapping with those of surrounding tissues. This overlapping is mainly due to the composition of bones and to the presence of some diseases such as Osteoarthritis, Osteoporosis, etc. Moreover, segmentation of bone structures is a very time-consuming task due to the 3D essence of the bones. Usually, this segmentation is implemented manually or with algorithms using simple techniques such as thresholding and thus providing bad results. In this paper gray information and 3D statistical information have been combined to be used as input to a continuous max- ow algorithm. Twenty CT images have been tested and di erent coe cients have been computed to assess the performance of our implementation. Dice and Sensitivity values above 0.91 and 0.97 respectively were obtained. A comparison with Level Sets and thresholding techniques has been carried out and our results outperformed them in terms of accuracy.es
dc.description.sponsorshipMinisterio de ciencia e innovación TEC2010-21619-C04-02es
dc.description.sponsorshipJunta de Andalucía P11-TIC-7727es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherSociety of Photo-optical Instrumentation Engineers (SPIE)es
dc.relation.ispartofSPIE. Photonics West (2015), p 94133Y-1-94133Y-6
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectSegmentationes
dc.subjectMax- flowes
dc.subjectOptimizationes
dc.titleSegmentation of bone structures in 3D CT images based on continuous max- ow optimizationes
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Teoría de la Señal y Comunicacioneses
dc.relation.projectIDTEC2010-21619-C04-02es
dc.relation.projectIDP11-TIC-7727es
dc.relation.publisherversionfile:///C:/Users/Rafa%20H.%20Pavo/Downloads/94133Y.pdfes
dc.identifier.doi10.1117/12.2082139es
idus.format.extent6 p.es
dc.publication.initialPage94133Y-1es
dc.publication.endPage94133Y-6es
dc.eventtitleSPIE. Photonics Westes
dc.eventinstitutionSan Franciscoes
dc.identifier.sisius21233816es

FicherosTamañoFormatoVerDescripción
94133Y.pdf348.6KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional