Tesis Doctoral

dc.contributor.advisorOliva Pascual-Vaca, Ángeles
dc.creatorGogorza Arroitaonandia, Cristóbales
dc.date.accessioned2018-05-28T17:46:20Z
dc.date.available2018-05-28T17:46:20Z
dc.date.issued2017-09-11
dc.identifier.citationGogorza Arroitaonandia, C. (2017). Efectos del dispositivo inybi en sujetos con acortamiento de isquiosurales. (Tesis Doctoral Inédita). Universidad de Sevilla, Sevilla.
dc.identifier.urihttps://hdl.handle.net/11441/75282
dc.description.abstractDiscernir si la aplicación del instrumento INYBI en la musculatura suboccipital es comparable a la aplicación de la técnica manual y determinar que no existen diferencias en cuanto a los resultados obtenidos en las variables examinadas en pacientes con acortamiento de musculatura isquiosural. Material y métodos.- Ensayo clínico aleatorizado, a doble ciego, longitudinal, prospectivo y controlado. Se incluyen en el estudio un total de 40 sujetos, 12 mujeres y 28 hombres; distribuidas de manera aleatoria en dos grupos, experimental (20), que recibió la aplicación instrumental INYBI en la musculatura suboccipital y control (20), que recibió la técnica manual de inhibición de la musculatura suboccipital. Sobre ambos grupos se toman medidas pre- y post- y post 20 min. de la goniometría cervical para amplitud de flexión (Clinometer Plaincode); test de Schober modificado-modificado para amplitud de flexión lumbar; test dedos-suelo para la amplitud de flexión de tronco; test de elevación de pierna extendida (medición digital y manual) para la amplitud de flexión de cadera y mediante un pie de rey la amplitud de la apertura de la boca. Resultados.- En ninguna de las variables estudiadas existen diferencias estadísticamente significativas entre el grupo experimental y el grupo control (p> 0,05). En el total de la muestra, encontramos diferencias significativas entre los momentos pre y los momentos post y post 20min en la flexión cervical (p < 0,001) y el test de Schober (p < 0,05); y encontramos diferencias significativas entre los momentos pre y el momento post 20min en test Dedos-suelo (p < 0,05), test de Elevación de la pierna recta (p < 0,05) (en ambas piernas y con medición digital y manual) y en la apertura de la boca (p < 0,05). Conclusiones.- La inhibición de la musculatura suboccipital produce cambios en el acortamiento de la cadena muscular posterior y no hay diferencias significativas entre la aplicación de la técnica manual y la aplicación del instrumento INYBI. El dispositivo INYBI tiene efectos beneficiosos en el tratamiento del acortamiento de la musculatura isquiosural.es
dc.description.abstractObjectives To discern whether the application of the INYBI instrument in the suboccipital musculature is comparable to the application of the manual technique and to determine that there are no differences in the results obtained in the variables examined in patients with ischiosural musculature shortening. Materials and methods Randomized, double-blind, longitudinal, prospective, and controlled trial. A total of 40 subjects were included in the study (12 women and 28 men), randomly distributed in two groups: experimental (20), which received the INYBI instrumental application in the suboccipital musculature; and control (20), which received the manual technique of inhibition of the suboccipital musculature. Pre- and post- and post-20-mins measurements of the cervical goniometry were taken on both groups for flexion amplitude (Clinometer Plaincode); modified Schober's test modified for lumbar flexion amplitude; fingertip-to-floor test for trunk flexion amplitude; extended leg elevation test (digital and manual measurement) for hip flexion amplitude; and the width of the opening of the mouth using a slide gauge. Results In none of the variables studied were there statistically significant differences between the experimental group and the control group (p> 0.05). In the total sample, we found significant differences between the pre-, post- and post-20-mins moments in cervical flexion (p <0.001) and Schober’s test (p <0.05); and we found significant differences between the pre- and post-20-mins moment in the fingertip-to-floor test (P <0.05), the extended leg elevation test (p <0.05) (in both legs and with digital and manual measurement) and in the opening of the mouth (p <0.05). Conclusions Inhibition of the suboccipital musculature produces changes in the shortening of the posterior muscle chain and there are no significant differences between the application of the manual technique and the application of the INYBI instrument. The INYBI device has beneficial effects in the treatment of ischiosural musculature shortening.es
dc.formatapplication/pdfes
dc.language.isospaes
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectInhibición de contactoes
dc.subjectMúsculos del cuelloes
dc.subjectMovimientoes
dc.subjectSistema musculo-esqueléticoes
dc.subjectContact inhibitiones
dc.subjectNeck muscleses
dc.subjectMovementes
dc.subjectMusculoskeletal systemes
dc.titleEfectos del dispositivo inybi en sujetos con acortamiento de isquiosuraleses
dc.typeinfo:eu-repo/semantics/doctoralThesises
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Fisioterapiaes
idus.format.extent85 p.es

FicherosTamañoFormatoVerDescripción
REPOSITORIO TESIS DOCTORAL ...1.599MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América
Excepto si se señala otra cosa, la licencia del ítem se describe como: Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América