Mostrar el registro sencillo del ítem

Artículo

dc.creatorQuesada Molina, José Manueles
dc.creatorEspino Navas, José Manueles
dc.creatorGallardo Fuentes, María Isabeles
dc.creatorCortés Giraldo, Miguel Antonioes
dc.creatorBattaglia, Maria Cristinaes
dc.creatorMiras, H.es
dc.creatorLallena Rojo, Antonio Migueles
dc.creatorGuirado, D.es
dc.creatorSchardt, D.es
dc.date.accessioned2017-08-17T10:18:41Z
dc.date.available2017-08-17T10:18:41Z
dc.date.issued2016-06-21
dc.identifier.citationQuesada Molina, J.M., Espino Navas, J.M., Gallardo Fuentes, M.I., Cortés Giraldo, M.A., Battaglia, M.C., Miras, H.,...,Schardt, D. (2016). Dosimetric response of radiochromic films to protons of low energies in the Bragg peak region. Physical Review Accelerators and Beams, 19 (6)
dc.identifier.issn2469-9888 (electrónico)es
dc.identifier.urihttp://hdl.handle.net/11441/63834
dc.description.abstractOne of the major advantages of proton or ion beams, applied in cancer treatment, is their excellent depth-dose profile exhibiting a low dose in the entrance channel and a distinct dose maximum (Bragg peak) near the end of range in tissue. In the region of the Bragg peak, where the protons or ions are almost stopped, experimental studies with low-energy particle beams and thin biological samples may contribute valuable information on the biological effectiveness in the stopping region. Such experiments, however, require beam optimization and special dosimetry techniques for determining the absolute dose and dose homogeneity for very thin biological samples. At the National Centre of Accelerators in Seville, one of the beam lines at the 3 MV Tandem Accelerator was equipped with a scattering device, a special parallel-plate ionization chamber with very thin electrode foils and target holders for cell cultures. In this work, we present the calibration in absolute dose of EBT3 films [Gafchromic radiotherapy films, http://www.ashland.com/products/gafchromic-radiotherapy-films] for proton energies in the region of the Bragg peak, where the linear energy transfer increases and becomes more significant for radiobiology studies, as well as the response of the EBT3 films for different proton energy values. To irradiate the films in the Bragg peak region, the energy of the beam was degraded passively, by interposing Mylar foils of variable thickness to place the Bragg peak inside the active layer of the film. The results obtained for the beam degraded in Mylar foils are compared with the dose calculated by means of the measurement of the beam fluence with an ionization chamber and the energy loss predicted by srim2008 code.es
dc.description.sponsorshipEU Initial Training Marie Curie Network FP7-PEOPLE-2011-ITN-289485es
dc.description.sponsorshipSpanish Research Projects No. FPA2014-53290-C2-2-Pes
dc.description.sponsorshipSpanish Research Projects No. FPA2013-47327-C2-1-Res
dc.description.sponsorshipAndalusian Research Project No. P12-FQM-1605es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherAmerican Physical Societyes
dc.relation.ispartofPhysical Review Accelerators and Beams, 19 (6)
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleDosimetric response of radiochromic films to protons of low energies in the Bragg peak regiones
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/289485es
dc.relation.projectIDFPA2014-53290-C2-2-Pes
dc.relation.projectIDFPA2013-47327-C2-1-Res
dc.relation.projectIDP12-FQM-1605es
dc.relation.publisherversionhttp://dx.doi.org/10.1103/PhysRevAccelBeams.19.064701es
dc.identifier.doi10.1103/PhysRevAccelBeams.19.064701es
idus.format.extent7 p.es
dc.journaltitlePhysical Review Accelerators and Beamses
dc.publication.volumen19es
dc.publication.issue6es

FicherosTamañoFormatoVerDescripción
Dosimetric response of radiochromic ...677.3KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional