Mostrar el registro sencillo del ítem

Artículo

dc.creatorCortés Giraldo, Miguel Antonioes
dc.creatorQuesada Molina, José Manueles
dc.creatorGallardo Fuentes, María Isabeles
dc.creatorEspino Navas, José Manueles
dc.creatorOvejero Mayoral, María Del Carmenes
dc.creatorRuiz Prieto, Manueles
dc.creatorArráns Lara, Rafaeles
dc.creatorGonzález Álvarez, Marcos Aurelioes
dc.creatorPérez Vega-Leal, Alfredoes
dc.creatorAbou-Haidar, Z.es
dc.date.accessioned2017-08-11T11:12:51Z
dc.date.available2017-08-11T11:12:51Z
dc.date.issued2012-04-23
dc.identifier.citationCortes Giraldo, M.A., Quesada Molina, J.M., Gallardo Fuentes, M.I., Espino Navas, J.M., Ovejero Mayoral, M.D.C., Ruiz Prieto, M.,...,Abou-Haidar, Z. (2012). Output factor determination for dose measurements in axial and perpendicular planes using a silicon strip detector. Physical Review Special Topics: Accelerators and Beams, 15 (4), 1-7.
dc.identifier.issn1098-4402es
dc.identifier.urihttp://hdl.handle.net/11441/63773
dc.description.abstractIn this work we present the output factor measurements of a clinical linear accelerator using a silicon strip detector coupled to a new system for complex radiation therapy treatment verification. The objective of these measurements is to validate the system we built for treatment verification. The measurements were performed at the Virgin Macarena University Hospital in Seville. Irradiations were carried out with a Siemens ONCOR (TM) linac used to deliver radiotherapy treatment for cancer patients. The linac was operating in 6 MV photon mode; the different sizes of the fields were defined with the collimation system provided within the accelerator head. The output factor was measured with the silicon strip detector in two different layouts using two phantoms. In the first, the active area of the detector was placed perpendicular to the beam axis. In the second, the innovation consisted of a cylindrical phantom where the detector was placed in an axial plane with respect to the beam. The measured data were compared with data given by a commercial treatment planning system. Results were shown to be in a very good agreement between the compared set of data.es
dc.description.sponsorshipEU Initial Training Marie Curie Network PITN-GA-2008-215080es
dc.description.sponsorshipSpanish Research Projects FPA2009-08848 FPA2008-04972-C03-02es
dc.description.sponsorshipgovernment of Andalusia Research PO7-FQM02894es
dc.description.sponsorshipConsolider-Ingenio CSD2007-00042es
dc.description.sponsorshipInstalaciones Inabensa S.A. 68/83 0214/0129es
dc.formatapplication/pdfes
dc.language.isoenges
dc.publisherAmerican Physical Societyes
dc.relation.ispartofPhysical Review Special Topics: Accelerators and Beams, 15 (4), 1-7.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleOutput factor determination for dose measurements in axial and perpendicular planes using a silicon strip detectores
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Electrónicaes
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/215080es
dc.relation.projectIDFPA2009-08848es
dc.relation.projectIDFPA2008-04972-C03-02es
dc.relation.projectIDPO7-FQM02894es
dc.relation.projectIDCSD2007-00042es
dc.relation.projectID68/83 0214/0129es
dc.relation.publisherversionhttp://dx.doi.org/10.1103/PhysRevSTAB.15.042802es
dc.identifier.doi10.1103/PhysRevSTAB.15.042802es
idus.format.extent7 p.es
dc.journaltitlePhysical Review Special Topics: Accelerators and Beamses
dc.publication.volumen15es
dc.publication.issue4es
dc.publication.initialPage1es
dc.publication.endPage7es

FicherosTamañoFormatoVerDescripción
Output factor determination for ...656.0KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional