Mostrar el registro sencillo del ítem

Ponencia

dc.creatorRíos-García, N.es
dc.creatorDurán, Mario J.es
dc.creatorGonzález Prieto, Ignacioes
dc.creatorMartín Torres, Cristinaes
dc.creatorBarrero, Federicoes
dc.date.accessioned2017-05-10T11:27:20Z
dc.date.available2017-05-10T11:27:20Z
dc.date.issued2017-04
dc.identifier.citationRíos-García, N., Durán, M.J., González Prieto, I., Martín Torres, C. y Barrero, F. (2017). An open-phase fault detection method for six-phase induction motor drives. En International Conference on Renewable Energ ies and Power Quality (ICREPQ’17 ). Renewable Energy and Power Quality Journal (RE&PQJ), No.15 April 2017, Málaga.
dc.identifier.issn2172-038Xes
dc.identifier.urihttp://hdl.handle.net/11441/59598
dc.descriptionMalaga (Spain), 4th to 6th April, 2017 Comunicaciones del Congreso Publicadas en: Renewable Energy and Power Quality Journal (RE&PQJ) ISSN 2172 038X, No.15 April 2017es
dc.description.abstractInduction machines (IM) with multiple sets of three-phase windings are a real alternative in safety- critical applications due to their inherent redundancy and extra number of freedom degrees. These properties can be used to devel op a fault-tolerant system without extra hardware. The fault detection is mandatory in the creation of a fault tolerant system. Since, the fault localization allows to adapt the control scheme of this anomalous mode of operation. Nowadays, open-phase faults (OPFs) and six-phase IMs are hot topics in the literature of fault-tolerant drives. Thus, this paper presents an open-phase fault detection method for a six-phase IM drive . The detection method is based o n the vector space decomposition (VSD), taking the components of the secondary orthogonal subspace to localize the open-phase fault. The goodness of the proposed method is validated with simulation resultses
dc.description.sponsorshipMinisterio de Ciencia e Innovacion ENE2014-52536-C2–1-Res
dc.formatapplication/pdfes
dc.language.isoenges
dc.relation.ispartofInternational Conference on Renewable Energ ies and Power Quality (ICREPQ’17 ). Renewable Energy and Power Quality Journal (RE&PQJ), No.15 April 2017 (2017), pp. 473-478.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMultiphase motor driveses
dc.subjectopen-phase faultes
dc.subjectfault detectiones
dc.subjectfault localizationes
dc.titleAn open-phase fault detection method for six-phase induction motor driveses
dc.typeinfo:eu-repo/semantics/conferenceObjectes
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Electrónicaes
dc.relation.projectIDENE2014-52536-C2–1-Res
dc.relation.publisherversionhttp://www.icrepq.com/icrepq17/358-17-rios.pdfes
dc.identifier.doi10.24084/repqj15.358es
dc.contributor.groupTIC-201 ACE-Ti: Aplicaciones Cibernéticas de la Electrónica a las Tecnologías de la Informaciónes
idus.format.extent6es
dc.publication.initialPage473es
dc.publication.endPage478es
dc.eventtitleInternational Conference on Renewable Energ ies and Power Quality (ICREPQ’17 ). Renewable Energy and Power Quality Journal (RE&PQJ), No.15 April 2017es
dc.eventinstitutionMálagaes
dc.contributor.funderMinisterio de Ciencia e Innovación (MICIN). España

FicherosTamañoFormatoVerDescripción
Barrero_ICREPQ17.pdf984.6KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional