Mostrar el registro sencillo del ítem

Artículo

dc.creatorHernández Mendoza, Héctor 
dc.creatorChamizo Calvo, Elena 
dc.creatorYllera, Abel 
dc.creatorGarcía León, Manuel 
dc.creatorDelgado, Antonio 
dc.date.accessioned2015-02-26T13:46:07Z
dc.date.available2015-02-26T13:46:07Z
dc.date.issued2010
dc.identifier.citationHernández Mendoza, H., Chamizo Calvo, E., Yllera, A., García León, M. y Delgado, A. (2010). A highly sensitive method for the reassessment and quantification of 239Pu in urine samples based on a 1 MV accelerator mass spectrometry system.
dc.identifier.issn0267-9477es
dc.identifier.issn1364-5544es
dc.identifier.urihttp://hdl.handle.net/11441/22779
dc.description.abstractA new and highly sensitive method for the determination of 239Pu in human urine has been developed permitting the reassessment of planchets initially prepared for alpha spectrometry (AS) analysis in the context of internal dosimetry. A set of urine samples (volume: 500 mL) was spiked with known quantities of 239Pu, ranging from 2 to 120 fg (4.6 mBq–0.3 mBq), employing 14 pg (2.05 mBq) of 242Pu as internal standard. The Pu was purified by ion-chromatography using BioRad AG1X2 anion-exchange resins (Bio-Rad Laboratories Inc.). The chemical yield was determined by alphaspectrometry, being about 80%. Afterwards, the planchets so obtained were leached with diluted HNO3 and the dissolved plutonium was determined by Accelerator Mass Spectrometry (AMS) at the Centro Nacional de Aceleradores (CNA) in Seville, Spain. The minimum detectable activity (MDA) for the AMS measurements was determined through the study of a set of procedural blanks, giving figures of about 0.44 fg (1 mBq) per sample. This contrasts with the MDA obtained by AS for the same set of samples, of about 50 fg (0.1 mBq). The results now presented helps to demonstrate that the routine measurement of 239Pu at ultra trace levels in human urine samples is possible with the new-generation of compact AMS systems, offering a highly sensitive method for the reassessing of planchets prepared for bioassay purposes.es
dc.formatapplication/pdfes
dc.language.isoenges
dc.relation.ispartofJournal of analytical atomic spectrometry, 25, 1410–1415es
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleA highly sensitive method for the reassessment and quantification of 239Pu in urine samples based on a 1 MV accelerator mass spectrometry systemes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Física Atómica, Molecular y Nucleares
dc.relation.publisherversion10.1039/c002420aes
dc.relation.publisherversion10.1039/c002420a
dc.identifier.idushttps://idus.us.es/xmlui/handle/11441/22779

FicherosTamañoFormatoVerDescripción
A highly sensitive method for ...250.3KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional