dc.identifier.citationAcosta García, I.J., Navarro Casas, J. y Sendra, J.J. (2013). Towards an analysis of the performance of lightwell skylights under overcast sky conditions. Energy and Buildings, 64, 10-16. https://doi.org/10.1016/j.enbuild.2013.04.009.
dc.identifier.issn0378-7788es
dc.identifier.issn1872-6178es
dc.identifier.urihttps://hdl.handle.net/11441/162861
dc.description.abstractThe main aim of this article is to analyze the performance of lightwell skylights under overcast sky conditions, determining the daylight factors and luminous distribution produced inside a room. Four different studies are carried out considering a room with a lightwell skylight. The first analyzes the daylight factors according to the size and height/width ratio of the skylight, the second evaluates illuminance depending on the reflection index of the lightwell, the third studies different room proportions and the fourth establishes suitable spacing between skylights. All tests were carried out using Lightscape 3.2 software. Following the trials, it was concluded that daylight factors are almost directly proportional to the size of the skylights and inversely proportional to their height. There is also an approximate quantification of the influence of the reflection index of the lightwell on interior lighting. Finally, it is confirmed that, in the absence of a reflected component, the suitable spacing between openings is proportional to the height/width ratio of the skylight.es
dc.formatapplication/pdfes
dc.format.extent15 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofEnergy and Buildings, 64, 10-16.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectSkylightes
dc.subjectLightwelles
dc.subjectDaylightinges
dc.subjectOvercast skyes
dc.subjectLighting softwarees
dc.titleTowards an analysis of the performance of lightwell skylights under overcast sky conditionses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas I (ETSA)es
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/abs/pii/S0378778813002442?via%3Dihubes
dc.identifier.doi10.1016/j.enbuild.2013.04.009es
dc.contributor.groupUniversidad de Sevilla. TEP130: Arquitectura, Patrimonio y Sostenibilidad: Acústica, Iluminación, Óptica y Energíaes
dc.journaltitleEnergy and Buildingses
dc.publication.volumen64es
dc.publication.initialPage10es
dc.publication.endPage16es

FicherosTamañoFormatoVerDescripción
Lightwell skylights.pdf1.451MbIcon   [PDF] Ver/Abrir   Versión aceptada

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional