Mostrar el registro sencillo del ítem
Artículo
Assessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study
dc.creator | Herrero-Climent, Mariano | es |
dc.creator | Santos García, Rocío | es |
dc.creator | Jaramillo Santos, María Reyes | es |
dc.creator | Romero Ruiz, Manuel María | es |
dc.creator | Fernández Palacín, Ana | es |
dc.creator | Lázaro-Calvo, Pedro | es |
dc.creator | Bullon, Pedro | es |
dc.creator | Ríos-Santos, J.V. | es |
dc.creator | Bullon, Pedro | es |
dc.date.accessioned | 2024-08-05T08:24:40Z | |
dc.date.available | 2024-08-05T08:24:40Z | |
dc.date.issued | 2013 | |
dc.identifier.citation | Herrero-Climent, M., Santos García, R., Jaramillo Santos, M.R., Romero Ruiz, M.M., Fernández Palacín, A., Lázaro-Calvo, P.,...,Bullon, P. (2013). Assessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study. Medicina oral, patología oral y cirugía bucal, 18 (6), 877-882. https://doi.org/10.4317/medoral.19120. | |
dc.identifier.issn | 1698-4447 | es |
dc.identifier.issn | 1698-6946 | es |
dc.identifier.uri | https://hdl.handle.net/11441/161893 | |
dc.description.abstract | Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. Objectives: Assess the Osstell ISQ system’s reliability (i.e., its measurement reproducibility and repeatability) by means of the intraclass correlation coefficient (ICC) as statistical method. Study Desing: Implants stability registers were completed by means of Osstell ISQ on 85 implants on 23 patients. Six measurements were completed on each implant by means of two different SmartPegs (types I and II); that is, three consecutive measurements with each transducer. Results: Average ISQ was 72.40, 72.22 and 72.79, and 72.06, 72.59 and 72.82 in the first, second, and third meas urements with SmartPegs I and II, respectively. Equal values or differences below three ISQ points were observed in 52.9% and 62.4% of the cases with SmartPegs I and II, respectively. The intraclass correlation coefficient was 0.97 for both SmartPegs, and repeatability and reproducibility also reached 0.97 for both SmartPegs. Conclusions: The RFA system Osstell ISQ presents almost perfect repeatability and reproducibility after intra class correlation coefficient analysis. Osstell ISQ measurements are highly reliable regarding reproducibility. Therefore, one measurement proves enough. | es |
dc.format | application/pdf | es |
dc.format.extent | 6 p. | es |
dc.language.iso | eng | es |
dc.publisher | Medicina oral S.L | es |
dc.relation.ispartof | Medicina oral, patología oral y cirugía bucal, 18 (6), 877-882. | |
dc.subject | Dental implants | es |
dc.subject | RFA | es |
dc.subject | ISQ | es |
dc.subject | Implant stability | es |
dc.subject | Osstell | es |
dc.title | Assessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study | es |
dc.type | info:eu-repo/semantics/article | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Estomatología | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Medicina Preventiva y Salud Pública | es |
dc.relation.publisherversion | http://www.medicinaoral.com/pubmed/medoralv18_i6_p877.pdf | es |
dc.identifier.doi | 10.4317/medoral.19120 | es |
dc.journaltitle | Medicina oral, patología oral y cirugía bucal | es |
dc.publication.volumen | 18 | es |
dc.publication.issue | 6 | es |
dc.publication.initialPage | 877 | es |
dc.publication.endPage | 882 | es |
Ficheros | Tamaño | Formato | Ver | Descripción |
---|---|---|---|---|
Assessment of Osstell ISQ’s.pdf | 325.2Kb | [PDF] | Ver/ | |
Este registro aparece en las siguientes colecciones
Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.