dc.identifier.citationHerrero-Climent, M., Santos García, R., Jaramillo Santos, M.R., Romero Ruiz, M.M., Fernández Palacín, A., Lázaro-Calvo, P.,...,Bullon, P. (2013). Assessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study. Medicina oral, patología oral y cirugía bucal, 18 (6), 877-882. https://doi.org/10.4317/medoral.19120.
dc.identifier.issn1698-4447es
dc.identifier.issn1698-6946es
dc.identifier.urihttps://hdl.handle.net/11441/161893
dc.description.abstractResonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. Objectives: Assess the Osstell ISQ system’s reliability (i.e., its measurement reproducibility and repeatability) by means of the intraclass correlation coefficient (ICC) as statistical method. Study Desing: Implants stability registers were completed by means of Osstell ISQ on 85 implants on 23 patients. Six measurements were completed on each implant by means of two different SmartPegs (types I and II); that is, three consecutive measurements with each transducer. Results: Average ISQ was 72.40, 72.22 and 72.79, and 72.06, 72.59 and 72.82 in the first, second, and third meas urements with SmartPegs I and II, respectively. Equal values or differences below three ISQ points were observed in 52.9% and 62.4% of the cases with SmartPegs I and II, respectively. The intraclass correlation coefficient was 0.97 for both SmartPegs, and repeatability and reproducibility also reached 0.97 for both SmartPegs. Conclusions: The RFA system Osstell ISQ presents almost perfect repeatability and reproducibility after intra class correlation coefficient analysis. Osstell ISQ measurements are highly reliable regarding reproducibility. Therefore, one measurement proves enough.es
dc.formatapplication/pdfes
dc.format.extent6 p.es
dc.language.isoenges
dc.publisherMedicina oral S.Les
dc.relation.ispartofMedicina oral, patología oral y cirugía bucal, 18 (6), 877-882.
dc.subjectDental implantses
dc.subjectRFAes
dc.subjectISQes
dc.subjectImplant stabilityes
dc.subjectOsstelles
dc.titleAssessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical studyes
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Medicina Preventiva y Salud Públicaes
dc.relation.publisherversionhttp://www.medicinaoral.com/pubmed/medoralv18_i6_p877.pdfes
dc.identifier.doi10.4317/medoral.19120es
dc.journaltitleMedicina oral, patología oral y cirugía bucales
dc.publication.volumen18es
dc.publication.issue6es
dc.publication.initialPage877es
dc.publication.endPage882es

FicherosTamañoFormatoVerDescripción
Assessment of Osstell ISQ’s.pdf325.2KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.