Mostrar el registro sencillo del ítem

Artículo

dc.creatorHerrero-Climent, Marianoes
dc.creatorDíaz Castro, Carmen Maríaes
dc.creatorChereguini Fernández, Carloses
dc.creatorFalcao, Carloses
dc.creatorGil, Francisco Javieres
dc.creatorRíos-Santos, J.V.es
dc.date.accessioned2024-08-01T10:58:06Z
dc.date.available2024-08-01T10:58:06Z
dc.date.issued2017
dc.identifier.citationHerrero-Climent, M., Díaz Castro, C.M., Chereguini Fernández, C., Falcao, C., Gil, F.J. y Ríos-Santos, J.V. (2017). Resonance frequency analysis by the Osstell system, using the transducer screwed to different healings abutments. Revista portuguesa de estomatologia medicina dentaria e cirurgia maxilofacial, 58 (2), 91-966. https://doi.org/10.24873/j.rpemd.2017.05.015.
dc.identifier.issn1646-2890es
dc.identifier.issn1647-6700es
dc.identifier.urihttps://hdl.handle.net/11441/161836
dc.description.abstractObjectives: compare the ISQ values obtained by the Osstell ISQ, screwing the Smarpeg directly to the implant or to the new designed healing abutments of 2, 3.5 and 5 mm of height. Methods: 60 rough surface implants were placed in 4 bovine ribs. 30 standard and 30 prototype implants were divided to group A and B, respectively. All were inserted with a torque of 30 N/ cm2, so that the rough/smooth interface was placed at bone crest level (the distance between the implants needed to be at least 4 mm). Primary stability was measured by resonance frequency analysis (RFA) with the Osstell ISQ transducer directly to the implant or over three Smartpeg screwed to the top of three different healing abutments of 2, 3.5 and 5 mm of height. Results: The mean ISQ of the prototype group is 73.9 ± 5.3 and of the standard one is 79.8 ± 3.7. The mean ISQ values according to where the Smartpeg is screwed to were 76.2 ± 4.47 and 75.69 ± 4.7 when the Smartpeg was screwed directly to the implant; 78.2 ± 5.78, 77.3 ± 5.90, 76.0 ± 5.90 when the transducer was screwed to the abutments of 2, 3.5 and 5 mm of height respectively. Conclusions: It may be concluded from the present investigation that similar ISQ values could be obtained measuring the RFA with the transducer screwed directly to the implant or to healing abutments of different heights, in an accurate and reproducible way. (Rev Port Esto matol Med Dent Cir Maxilofac. 2017;58(2):91-96.es
dc.formatapplication/pdfes
dc.format.extent6 p.es
dc.language.isoenges
dc.publisherSPEMD-Sociedad portuguesa estomatologia & medicina dentariaes
dc.relation.ispartofRevista portuguesa de estomatologia medicina dentaria e cirurgia maxilofacial, 58 (2), 91-966.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectAbutment designes
dc.subjectBone implant interfacees
dc.subjectDental implantses
dc.subjectOsseointegrationes
dc.titleResonance frequency analysis by the Osstell system, using the transducer screwed to different healings abutmentses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.relation.publisherversionhttps://revista.spemd.pt/article/21es
dc.identifier.doi10.24873/j.rpemd.2017.05.015es
dc.journaltitleRevista portuguesa de estomatologia medicina dentaria e cirurgia maxilofaciales
dc.publication.volumen58es
dc.publication.issue2es
dc.publication.initialPage91es
dc.publication.endPage966es

FicherosTamañoFormatoVerDescripción
Resonance frequency analysis by ...346.8KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional