Resumen | Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental
implant stability).
Objective: Few studies assess repeatability and reproducibility in resonance ... Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive measurements were registered with each transducer. Results: Average ISQ varied from 72.43 to 72.60 and 73.26 in the first, second and third measurements, respectively with the SamrtPeg I and from 72.98 to 73.26 and 73.74 in the first, second and third measurements, respectively with the SamrtPeg II . Exactly equal values were observed in 10.43 and 12.1% of the cases with Smart-Pegs I and II, respectively. The intraclass correlation coefficient was 0.96 and 0.96 for Smart Pegs I and II, respectively. Repeatability and reproducibility was 0.97 for both Smart-Pegs I and II. Conclusions: The RFA system contributed by Osstell Mentor® renders almost perfect reproducibility and repeatability, as proven by statistical analysis carried out by means of ICC with 95% confidence level. This instrument contributes highly reliable RFA measurements in dental implants. |
Cita | Herrero-Climent, M., Albertini, M., Ríos-Santos, J.V., Lázaro-Calvo, P., Fernández Palacín, A. y Bullon, P. (2012). Resonance frequency analysis-reliability in third generation instruments: Osstell mentor R. Medicina oral, patología oral y cirugía bucal, 17 (5), E801-E806. https://doi.org/0.4317/medoral.17861. |
Ficheros | Tamaño | Formato | Ver | Descripción |
---|---|---|---|---|
Resonance frequency analysis-r ... | 386.1Kb | [PDF] | Ver/ | |
Este registro aparece en las siguientes colecciones
Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.