Mostrar el registro sencillo del ítem

Artículo

dc.creatorSáinz Bueno, José Antonioes
dc.creatorFernández Palacín, Anaes
dc.creatorBorrero González, Carlotaes
dc.creatorAquise, Adrianaes
dc.creatorRamos, Zenaidaes
dc.creatorGarcía Mejido, José Antonioes
dc.date.accessioned2024-07-23T08:12:58Z
dc.date.available2024-07-23T08:12:58Z
dc.date.issued2018
dc.identifier.citationSáinz Bueno, J.A., Fernández Palacín, A., Borrero González, C., Aquise, A., Ramos, Z. y García Mejido, J.A. (2018). Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing. Journal of obstetrics and gynaecology, 38 (3), 333-338. https://doi.org/10.1080/01443615.2017.1354179.
dc.identifier.issn0144-3615es
dc.identifier.issn1364-6893es
dc.identifier.urihttps://hdl.handle.net/11441/161624
dc.description.abstractThe aim of this study was to evaluate the inter- and intraobserver correlation of the different intrapartum-transperineal-ultrasound-parameters(ITU) (angle of progression (AoP), progression-distance (PD), head-direction (HD), midline-angle (MLA) and head-perineum distance (HPD)) with contraction and pushing. We evaluated 28 nulliparous women at full dilatation under epidural analgesia. We performed a transperineal ultrasound evaluating AoP and PD in the longitudinal plane, and MLA and HPD in the transverse plane. Interclass correlation coefficients (ICC) with 95% CIs and Bland–Altman analysis were used to assess intra- and interobserver measurement’s repeatability. The ICC of the ITU for the same observer was adequate for all the parameters (p < .005) AoP 0.98 (95%CI, 0.96–0.99), PD 0.98 (95%CI, 0.97–0.99), MLA 0.99 (95%CI, 0.97–0.99), HPD 0.96 (95%CI, 0.88–0.99). The ICC of the ITU for interobserver was: AoP 0.93 (95%CI, 0.79–0.98), PD 0.92 (95%CI, 0.76–0.97), MLA 0.77 (95%CI, 0.42–0.92), HPD 0.47 (95%CI, −0.12–0.8). The HD had an interobserver correlation of 0.53 (95%CI, 0.1–0.9) (Kappa C). The mean difference of the AoP was 2.42°, of the PD 1 mm and 0.28° MLA (Bland–Altman test). ITU has an adequate intra- and interobserver correlation for its use with contraction and pushing under epidural analgesia.es
dc.formatapplication/pdfes
dc.format.extent6 p.es
dc.language.isoenges
dc.publisherInforma Healthcarees
dc.relation.ispartofJournal of obstetrics and gynaecology, 38 (3), 333-338.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIntrapartum ultrasound, labores
dc.subjectPushinges
dc.subjectTranslabial ultrasoundes
dc.subjectTransperineal ultrasoundes
dc.titleIntra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushinges
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Cirugíaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Medicina Preventiva y Salud Públicaes
dc.relation.publisherversionhttps://www.tandfonline.com/doi/full/10.1080/01443615.2017.1354179es
dc.identifier.doi10.1080/01443615.2017.1354179es
dc.journaltitleJournal of obstetrics and gynaecologyes
dc.publication.volumen38es
dc.publication.issue3es
dc.publication.initialPage333es
dc.publication.endPage338es

FicherosTamañoFormatoVerDescripción
INTRA AND INTEROBSERVER Acepta ...1.036MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional