Article
Influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle avulsion identified by 3–4 d transperineal ultrasound
Author/s | García Mejido, José Antonio
Fuente Vaquero, Paloma de la Fernández Palacín, Ana Aquise Pino, Adriana Bonomi Barby, María José Sáinz Bueno, José Antonio |
Department | Universidad de Sevilla. Departamento de Cirugía Universidad de Sevilla. Departamento de Medicina Preventiva y Salud Pública. |
Publication Date | 2018 |
Deposit Date | 2024-07-23 |
Published in |
|
Abstract | Objectives: Evaluation of the influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle (LAM) avulsions.
Materials and methods: Prospective observational study with 86 nulliparous women ... Objectives: Evaluation of the influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle (LAM) avulsions. Materials and methods: Prospective observational study with 86 nulliparous women with at term gestation who required instrumentation with vacuum to complete fetal extraction. After every delivery, each explorer reported the number of vacuum tractions needed to complete fetal extraction, as well as the subjective complexity of the instrumentation. LAM avulsion rate was assessed by 3D–4D transperineal ultrasound evaluation 6 months after delivery. Results: Seventy nine cases were evaluated and classified as either “easy” delivery (below three vacuum tractions; n = 49) or “difficult” delivery (three or more vacuum tractions; n = 30). No differences in obstetric characteristics were observed between study groups, with the following exceptions: fetal head circumference (34.8 ± 2.7 versus 35.2 ± 1.1; p = .013) and fetal weight at birth (3260 ± 421 versus 3500 ± 421; p = .016). No statistically significant differences between study groups were observed in LAM avulsion rate (36.7 versus 30%) and levator hiatus area (cm2) at rest (18.44 ± 3.95 versus 17.75 ± 3.90). Conclusions: The number of vacuum tractions needed to complete fetal extraction is not associated to a higher LAM avulsion rate nor with differences in levator hiatus area. |
Citation | García Mejido, J.A., Fuente Vaquero, P.d.l., Fernández Palacín, A., Aquise Pino, A., Bonomi Barby, M.J. y Sáinz Bueno, J.A. (2018). Influence of difficulty of instrumentation with vacuum on the rate of levator ani muscle avulsion identified by 3–4 d transperineal ultrasound. The Journal of Maternal-Fetal & Neonatal Medicine, 31 (5), 591-596. https://doi.org/10.1080/14767058.2017.1293022. |
Files | Size | Format | View | Description |
---|---|---|---|---|
NFLUENCE OF DIFFICULTY OF ... | 767.3Kb | [PDF] | View/ | |