Mostrar el registro sencillo del ítem

Artículo

dc.creatorGarcía Mejido, José Antonioes
dc.creatorBorrero González, Carlotaes
dc.creatorPamela, Valdiviesoes
dc.creatorAquise, Adrianaes
dc.creatorSerrano, Rosaes
dc.creatorSáinz Bueno, José Antonioes
dc.date.accessioned2024-07-22T10:24:40Z
dc.date.available2024-07-22T10:24:40Z
dc.date.issued2014
dc.identifier.citationGarcía Mejido, J.A., Borrero González, C., Pamela, V., Aquise, A., Serrano, R. y Sáinz Bueno, J.A. (2014). Utility of Intrapartum Transabdominal Ultrasound for the Correct Placement of Vacuum during Assisted Delivery. Current womens health reviews, 10 (1), 33-378. https://doi.org/10.2174/1573404810666140930235648.
dc.identifier.issn1573-4048es
dc.identifier.issn1875-6581es
dc.identifier.urihttps://hdl.handle.net/11441/161602
dc.description.abstractObjectives: To correlate the identification of fetal head position through digital examination (DE) and transabdominal ultrasound (TAU) prior to vacuum delivery. A secondary objective was to recognize how knowledge of the exact fetal head position affects the placement of the cup. Method: Women in active labor at term with normal singleton cephalic fetus were included. Transvaginal digital examination was performed and followed immediately by transabdominal ultrasound assessment. After birth, the distance between the center of the chignon and the flexion point was measured on the newborn. Results: 81 cases were included. TAU identified the fetal head position in 100% of cases and the DE in 96.3%. In 71.5% (58/81) patients DE was consistent with TAU. 100% of these cases were occiput anterior positions and 60% occiput posterior. Placing the cup in a flexing position, the lateral deviation was 0.7+/-0.5cm and the distance between the center of the chignon and the flexion point was 1.6+/-1.0cm, The center of the chignon was accurately placed at less than 2cm posterior to the flexion point in 92.5% (75/81) of the cases. Conclusions: Using DE only the vacuum cup was placed inaccurately in 1 of every 4 cases. The employment of TAU improved this result to 1 in 10.es
dc.formatapplication/pdfes
dc.format.extent5 p.es
dc.language.isoenges
dc.publisherBentham Science Publishing LTDes
dc.relation.ispartofCurrent womens health reviews, 10 (1), 33-378.
dc.subjectDeliveryes
dc.subjectIntrapartum ultrasoundes
dc.subjectVacuumes
dc.titleUtility of Intrapartum Transabdominal Ultrasound for the Correct Placement of Vacuum during Assisted Deliveryes
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Cirugíaes
dc.relation.publisherversionhttps://www.eurekaselect.com/article/62603es
dc.identifier.doi10.2174/1573404810666140930235648es
dc.journaltitleCurrent womens health reviewses
dc.publication.volumen10es
dc.publication.issue1es
dc.publication.initialPage33es
dc.publication.endPage378es

FicherosTamañoFormatoVerDescripción
Utility of intrapartum Aceptada ...743.4KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Este documento está protegido por los derechos de propiedad intelectual e industrial. Sin perjuicio de las exenciones legales existentes, queda prohibida su reproducción, distribución, comunicación pública o transformación sin la autorización del titular de los derechos, a menos que se indique lo contrario.