dc.contributor.advisor | | |
dc.creator | Matos Garrido, Nuno | es |
dc.creator | Moreno Silvan, Mayte | es |
dc.creator | Ayllón Guerola, Juan Manuel | es |
dc.creator | Jiménez Guerra, Álvaro | es |
dc.creator | Ortiz García, Iván | es |
dc.creator | España López, Antonio | es |
dc.creator | Segura Egea, Juan José | es |
dc.creator | Velasco-Ortega, Eugenio | es |
dc.date.accessioned | 2024-07-17T09:35:36Z | |
dc.date.available | 2024-07-17T09:35:36Z | |
dc.date.issued | 2017-07-12 | |
dc.identifier.citation | Matos Garrido, N., Moreno Silvan, M., Ayllón Guerola, J.M., Jiménez Guerra, Á., Ortiz García, I., España López, A.,...,Velasco-Ortega, E. (2017). Influencia de la fatiga cíclica en las conexiones internas implante-pilar. Avances en Odontoestomatologia, 33 (5), 221-229. | |
dc.identifier.issn | 0213-1285 | es |
dc.identifier.uri | https://hdl.handle.net/11441/161457 | |
dc.description.abstract | Introducción:
La conexión implante-pilar ha sido sugerida como crucial para el éxito a largo plazo de la oseointegración y para prevenir futuras complicaciones. El objetivo de este estudio fue evaluar la influencia de los tests de fatiga cíclica en el comportamiento de las conexiones internas implante-pilar.
Métodos:
Fueron divididos 50 implantes de titanio de conexión interna en 3 grupos: conexión octogonal (OC); doble conexión hexagonal (DHC), y conexión hexagonal (HC) con sus respectivos pilares. Los pilares fueron apretados con una llave de torque a 30 Ncm. Una carga cíclica entre 550 N y 135 N fue aplicada con un ángulo de 30º de forma axial dependiendo del sistema de implantes durante 5 millones de ciclos.
Resultados:
Los tests biomecánicos muestran una fractura de los implantes a una carga límite de 325 N de OC implantes; de 150 N en los DHC implantes y 135 N en HC implantes. La fracturas aparecieron en la zona de unión entre el cuello y el cuerpo del implante. No se han encontrado fracturas en los pilares ni en los tornillos de conexión.
Conclusiones:
Los resultados de este estudio indican que los ciclos de fatiga cíclica son importantes para evaluar la respuesta biomecánica de las diferentes conexiones implante-pilar de los sistemas de implantes. | es |
dc.description.abstract | Introduction:
The connection implant-abutment has been suggested to be crucial for the long-term success of osseointegration and to prevent future complications. The aim of this study was to evaluate the influence of fatigue cyclic test in the behavior of internal connection implant-abutment.
Methods:
Fifty titanium implants with internal connections were divided in 3 groups: octogonal connection (OC); double hexagonal connection (DHC); and hexagonal connection (HC) and with their respective abutments. Abutments were tightened to 30 Ncm with a torque controller. A cyclic load between 550 N and 135N according to different implant systems at a 30-degree angle to the long axis was applied to the implants for a 5 million cycles.
Results:
Biomechanical testing showed implant fracture in a limit load of 325 N of OC implants; in 150 N of DHC implants and 135 N of HC implants. Fracture cracks were located in the area between neck and body of implants. No abutments and screws retention fractures were found.
Conclusions:
Results of this study indicate that fatigue cyclic tests are important to evaluate the biomechanical behavior of different connection implants-abutments of several implants systems. | es |
dc.format | application/pdf | es |
dc.format.extent | 9 p. | es |
dc.language.iso | spa | es |
dc.publisher | Avances Ediciones | es |
dc.relation.ispartof | Avances en Odontoestomatologia, 33 (5), 221-229. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | implantes dentales | es |
dc.subject | carga cíclica | es |
dc.subject | test de fatiga | es |
dc.subject | biomecánica | es |
dc.subject | conexión implante-pilar | es |
dc.subject | implantología oral | es |
dc.subject | dental implants | es |
dc.subject | cyclic loading | es |
dc.subject | fatigue test | es |
dc.subject | biomechanics | es |
dc.subject | implant-abutment connection | es |
dc.subject | implant dentistry | es |
dc.title | Influencia de la fatiga cíclica en las conexiones internas implante-pilar | es |
dc.title.alternative | Influence of the cyclic fatigue in the implant-abutment internal connections | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.relation | Departamento de Ingeniería Mecánica y Fabricación | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Estomatología | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Ingeniería Mecánica y de Fabricación | es |
dc.relation.publisherversion | https://scielo.isciii.es/scielo.php?script=sci_arttext&pid=S0213-12852017000500006 | es |
dc.journaltitle | Avances en Odontoestomatologia | es |
dc.publication.volumen | 33 | es |
dc.publication.issue | 5 | es |
dc.publication.initialPage | 221 | es |
dc.publication.endPage | 229 | es |