dc.identifier.citationMatos Garrido, N., Moreno Silvan, M., Ayllón Guerola, J.M., Jiménez Guerra, Á., Ortiz García, I., España López, A.,...,Velasco-Ortega, E. (2017). Influencia de la fatiga cíclica en las conexiones internas implante-pilar. Avances en Odontoestomatologia, 33 (5), 221-229.
dc.identifier.issn0213-1285es
dc.identifier.urihttps://hdl.handle.net/11441/161457
dc.description.abstractIntroducción: La conexión implante-pilar ha sido sugerida como crucial para el éxito a largo plazo de la oseointegración y para prevenir futuras complicaciones. El objetivo de este estudio fue evaluar la influencia de los tests de fatiga cíclica en el comportamiento de las conexiones internas implante-pilar. Métodos: Fueron divididos 50 implantes de titanio de conexión interna en 3 grupos: conexión octogonal (OC); doble conexión hexagonal (DHC), y conexión hexagonal (HC) con sus respectivos pilares. Los pilares fueron apretados con una llave de torque a 30 Ncm. Una carga cíclica entre 550 N y 135 N fue aplicada con un ángulo de 30º de forma axial dependiendo del sistema de implantes durante 5 millones de ciclos. Resultados: Los tests biomecánicos muestran una fractura de los implantes a una carga límite de 325 N de OC implantes; de 150 N en los DHC implantes y 135 N en HC implantes. La fracturas aparecieron en la zona de unión entre el cuello y el cuerpo del implante. No se han encontrado fracturas en los pilares ni en los tornillos de conexión. Conclusiones: Los resultados de este estudio indican que los ciclos de fatiga cíclica son importantes para evaluar la respuesta biomecánica de las diferentes conexiones implante-pilar de los sistemas de implantes.es
dc.description.abstractIntroduction: The connection implant-abutment has been suggested to be crucial for the long-term success of osseointegration and to prevent future complications. The aim of this study was to evaluate the influence of fatigue cyclic test in the behavior of internal connection implant-abutment. Methods: Fifty titanium implants with internal connections were divided in 3 groups: octogonal connection (OC); double hexagonal connection (DHC); and hexagonal connection (HC) and with their respective abutments. Abutments were tightened to 30 Ncm with a torque controller. A cyclic load between 550 N and 135N according to different implant systems at a 30-degree angle to the long axis was applied to the implants for a 5 million cycles. Results: Biomechanical testing showed implant fracture in a limit load of 325 N of OC implants; in 150 N of DHC implants and 135 N of HC implants. Fracture cracks were located in the area between neck and body of implants. No abutments and screws retention fractures were found. Conclusions: Results of this study indicate that fatigue cyclic tests are important to evaluate the biomechanical behavior of different connection implants-abutments of several implants systems.es
dc.formatapplication/pdfes
dc.format.extent9 p.es
dc.language.isospaes
dc.publisherAvances Edicioneses
dc.relation.ispartofAvances en Odontoestomatologia, 33 (5), 221-229.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectimplantes dentaleses
dc.subjectcarga cíclicaes
dc.subjecttest de fatigaes
dc.subjectbiomecánicaes
dc.subjectconexión implante-pilares
dc.subjectimplantología orales
dc.subjectdental implantses
dc.subjectcyclic loadinges
dc.subjectfatigue testes
dc.subjectbiomechanicses
dc.subjectimplant-abutment connectiones
dc.subjectimplant dentistryes
dc.titleInfluencia de la fatiga cíclica en las conexiones internas implante-pilares
dc.title.alternativeInfluence of the cyclic fatigue in the implant-abutment internal connectionses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.relationDepartamento de Ingeniería Mecánica y Fabricación
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Ingeniería Mecánica y de Fabricaciónes
dc.relation.publisherversionhttps://scielo.isciii.es/scielo.php?script=sci_arttext&pid=S0213-12852017000500006es
dc.journaltitleAvances en Odontoestomatologiaes
dc.publication.volumen33es
dc.publication.issue5es
dc.publication.initialPage221es
dc.publication.endPage229es

FicherosTamañoFormatoVerDescripción
Influencia de la fatiga cíclica ...2.745MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional