dc.creator | Hernández Lucena, J. | es |
dc.creator | Alonso Aliste, F. | es |
dc.creator | Amián Cordero, J. | es |
dc.creator | Sánchez González, José María | es |
dc.date.accessioned | 2024-06-18T17:21:07Z | |
dc.date.available | 2024-06-18T17:21:07Z | |
dc.date.issued | 2024 | |
dc.identifier.citation | Hernández Lucena, J., Alonso Aliste, F., Amián Cordero, J. y Sánchez González, J.M. (2024). Outcomes of Corneal Compound Myopic Astigmatism with Presbyopia by Zeiss PRESBYOND® Laser Blended Vision LASIK Using Default CRS-Master® Target Refractions for Reduced Anisometropia. Journal of Clinical Medicine, 13 (10), 3011. https://doi.org/10.3390/jcm13103011. | |
dc.identifier.issn | 2077-0383 | es |
dc.identifier.uri | https://hdl.handle.net/11441/160664 | |
dc.description.abstract | Background/Objectives: Presbyopia, a common age-related refractive error, affects over a billion people globally and significantly impacts daily life. Methods: This retrospective study analyzed 288 eyes of 144 patients undergoing LBV PRESBYOND® treatment for myopic presbyopia with astigmatism, aiming to evaluate precision, efficacy, safety, and stability over six months. Results: Key findings include high efficacy, with 99% of distance-eyes achieving uncorrected distance visual acuity (UDVA) of 20/25 or better, and 85% of near-eyes achieving UDVA of 20/32 or better. The results show excellent refractive outcomes, with 99% of long-sighted eyes and 97% of near-sighted eyes having a postoperative spherical equivalent within ±1.00 D. Safety was demonstrated by no loss of two or more Snellen lines after treatment, with 94% of patients maintaining corrected distance visual acuity (CDVA) before and after surgery. Conclusions: Overall, LBV PRESBYOND® proved effective, safe, and well tolerated for myopic presbyopia correction, offering satisfactory visual outcomes and potential spectacle independence for various distances. This study underscores the importance of individualized treatment based on patient age, highlighting the positive impact of binocular summation on visual function. This study contributes to the growing body of evidence supporting LBV PRESBYOND® as a viable option for addressing presbyopic myopia, offering insights into its efficacy and safety profile. Further research could explore postoperative stereopsis and long-term outcomes to enhance understanding and refine treatment protocols. | es |
dc.format | application/pdf | es |
dc.format.extent | 13 p. | es |
dc.language.iso | eng | es |
dc.publisher | Multidisciplinary Digital Publishing Institute (MDPI) | es |
dc.relation.ispartof | Journal of Clinical Medicine, 13 (10), 3011. | |
dc.rights | Atribución 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.subject | Binocular summation | es |
dc.subject | Corrected distance visual acuity (CDVA) | es |
dc.subject | Myopic presbyopes | es |
dc.subject | PRESBYOND® Laser Blended Vision | es |
dc.subject | Micro-anisometropia | es |
dc.subject | Presbyopia treatments | es |
dc.subject | Uncorrected distance visual acuity (UDVA) | es |
dc.title | Outcomes of Corneal Compound Myopic Astigmatism with Presbyopia by Zeiss PRESBYOND® Laser Blended Vision LASIK Using Default CRS-Master® Target Refractions for Reduced Anisometropia | es |
dc.type | info:eu-repo/semantics/article | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Física de la Materia Condensada | es |
dc.relation.publisherversion | https://doi.org/10.3390/jcm13103011 | es |
dc.identifier.doi | 10.3390/jcm13103011 | es |
dc.journaltitle | Journal of Clinical Medicine | es |
dc.publication.volumen | 13 | es |
dc.publication.issue | 10 | es |
dc.publication.initialPage | 3011 | es |