Mostrar el registro sencillo del ítem

Artículo

dc.creatorAguilar Aguilera, Antonio Jesúses
dc.creatorHoz Torres, María Luisa de laes
dc.creatorCosta, Nélsones
dc.creatorArezes, Pedroes
dc.creatorMartínez Aires, María Doloreses
dc.creatorRuiz Padillo, Diego Pabloes
dc.date.accessioned2024-06-18T09:36:10Z
dc.date.available2024-06-18T09:36:10Z
dc.date.issued2022-07-01
dc.identifier.citationAguilar Aguilera, A.J., Hoz Torres, M.L.d.l., Costa, N., Arezes, P., Martínez Aires, M.D. y Ruiz Padillo, D.P. (2022). Assessment of ventilation rates inside educational buildings in Southwestern Europe: Analysis of implemented strategic measures. Journal of Building Engineering, 51 (104204). https://doi.org/10.1016/j.jobe.2022.104204.
dc.identifier.issn2352-7102es
dc.identifier.urihttps://hdl.handle.net/11441/160612
dc.description.abstractThe pandemic caused by COVID-19 has highlighted the need to ensure good indoor air quality. Public buildings (educational buildings in particular) have come under the spotlight because students, teachers and staff spend long periods of the day indoors. This study presents a measurement campaign for the assessment of ventilation rate (VR) and ventilation strategies in educational buildings in Southwestern Europe, Portugal and Spain. A representative sample of the teaching spaces of the Azurém Campus (Guimarães, Portugal) and the Fuentenueva Campus (Granada, Spain) have been analyzed. Natural ventilation is the predominant ventilation strategy in these spaces, being the most common strategy in educational buildings in Europe. VR was estimated under different configurations, using the CO2 decay method. Subsequently, the CO2 concentration was estimated according to occupancy and the probability of infection risk was calculated using the Wells-Riley equation. The obtained VR varied between 2.9 and 20.1 air change per hour (ACH) for natural cross ventilation, 2.0 to 5.1 ACH for single-sided ventilation and 1.8 to 3.5 for mechanically ventilated classrooms. Large differences in CO2 concentrations were verified, depending on the analyzed ventilation strategy, ranging from 475 to 3903 ppm for the different scenarios. However, the probability of risk was less than 1% in almost all of the classrooms analyzed. The results obtained from the measurement campaign showed that the selection of an appropriate ventilation strategy can provide sufficient air renewal and maintain a low risk of infection. Ventilation strategies need to be reconsidered as a consequence of the health emergency arising from the COVID-19 pandemic.es
dc.formatapplication/pdfes
dc.format.extent15 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofJournal of Building Engineering, 51 (104204).
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectBuildingses
dc.subjectVentilation assessmentes
dc.subjectSafety managementes
dc.subjectIndoor environmental qualityes
dc.subjectWell-beinges
dc.titleAssessment of ventilation rates inside educational buildings in Southwestern Europe: Analysis of implemented strategic measureses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas II (ETSIE)es
dc.relation.projectIDB-TEP-362-UGR18es
dc.relation.projectIDPID2019-108761RB-I00es
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S2352710222002170?via%3Dihubes
dc.identifier.doi10.1016/j.jobe.2022.104204es
dc.contributor.groupUniversidad de Sevilla. TEP968: Tecnologías para la Economía Circulares
dc.journaltitleJournal of Building Engineeringes
dc.publication.volumen51es
dc.publication.issue104204es
dc.contributor.funderMinisterio de Ciencia, Innovación y Universidades (MICINN). Españaes
dc.contributor.funderConsejo General de la Arquitectura Técnica (CGATE)es
dc.contributor.funderJunta de Andalucíaes
dc.contributor.funderAgencia Estatal de Investigación. Españaes
dc.contributor.funderEuropean Commission (EC). Fondo Europeo de Desarrollo Regional (FEDER)es

FicherosTamañoFormatoVerDescripción
Assessment of ventilation rates ...3.827MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional